Addressing #7552
When M405 is used it changes 'volumetric_multiplier[FILAMENT_SENSOR_EXTRUDER_NUM]' value. When M406 disables M405 it leaves the value unchanged. This PR applies 'calculate_volumetric_multipliers' in M406 instead of resetting it to 1.0 because M200 may not be compatible with M405 hence I'm sure to restore anyway with correct value.
This commit is contained in:
parent
2b12093589
commit
0067bb2840
1 changed files with 4 additions and 1 deletions
|
@ -9241,7 +9241,10 @@ inline void gcode_M400() { stepper.synchronize(); }
|
|||
/**
|
||||
* M406: Turn off filament sensor for control
|
||||
*/
|
||||
inline void gcode_M406() { filament_sensor = false; }
|
||||
inline void gcode_M406() {
|
||||
filament_sensor = false;
|
||||
calculate_volumetric_multipliers(); // Restore correct 'volumetric_multiplier' value
|
||||
}
|
||||
|
||||
/**
|
||||
* M407: Get measured filament diameter on serial output
|
||||
|
|
Reference in a new issue