Move SENSORLESS_PROBING to the probes section
Fixes a bug with HAS_BED_PROBE not being set before use.
This commit is contained in:
parent
7e58739a1f
commit
0578e9b16e
2 changed files with 8 additions and 8 deletions
|
@ -925,6 +925,14 @@
|
||||||
#define SMART_EFFECTOR_MOD_PIN -1 // Connect a GPIO pin to the Smart Effector MOD pin
|
#define SMART_EFFECTOR_MOD_PIN -1 // Connect a GPIO pin to the Smart Effector MOD pin
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
/**
|
||||||
|
* Use StallGuard2 to probe the bed with the nozzle.
|
||||||
|
* Requires stallGuard-capable Trinamic stepper drivers.
|
||||||
|
* CAUTION: This can damage machines with Z lead screws.
|
||||||
|
* Take extreme care when setting up this feature.
|
||||||
|
*/
|
||||||
|
//#define SENSORLESS_PROBING
|
||||||
|
|
||||||
//
|
//
|
||||||
// For Z_PROBE_ALLEN_KEY see the Delta example configurations.
|
// For Z_PROBE_ALLEN_KEY see the Delta example configurations.
|
||||||
//
|
//
|
||||||
|
|
|
@ -2308,14 +2308,6 @@
|
||||||
*/
|
*/
|
||||||
//#define SENSORLESS_HOMING // StallGuard capable drivers only
|
//#define SENSORLESS_HOMING // StallGuard capable drivers only
|
||||||
|
|
||||||
/**
|
|
||||||
* Use StallGuard2 to probe the bed with the nozzle.
|
|
||||||
*
|
|
||||||
* CAUTION: This could cause damage to machines that use a lead screw or threaded rod
|
|
||||||
* to move the Z axis. Take extreme care when attempting to enable this feature.
|
|
||||||
*/
|
|
||||||
//#define SENSORLESS_PROBING // StallGuard capable drivers only
|
|
||||||
|
|
||||||
#if EITHER(SENSORLESS_HOMING, SENSORLESS_PROBING)
|
#if EITHER(SENSORLESS_HOMING, SENSORLESS_PROBING)
|
||||||
// TMC2209: 0...255. TMC2130: -64...63
|
// TMC2209: 0...255. TMC2130: -64...63
|
||||||
#define X_STALL_SENSITIVITY 8
|
#define X_STALL_SENSITIVITY 8
|
||||||
|
|
Reference in a new issue