Move SENSORLESS_PROBING to the probes section
Fixes a bug with HAS_BED_PROBE not being set before use.
This commit is contained in:
parent
7e58739a1f
commit
0578e9b16e
2 changed files with 8 additions and 8 deletions
|
@ -925,6 +925,14 @@
|
|||
#define SMART_EFFECTOR_MOD_PIN -1 // Connect a GPIO pin to the Smart Effector MOD pin
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use StallGuard2 to probe the bed with the nozzle.
|
||||
* Requires stallGuard-capable Trinamic stepper drivers.
|
||||
* CAUTION: This can damage machines with Z lead screws.
|
||||
* Take extreme care when setting up this feature.
|
||||
*/
|
||||
//#define SENSORLESS_PROBING
|
||||
|
||||
//
|
||||
// For Z_PROBE_ALLEN_KEY see the Delta example configurations.
|
||||
//
|
||||
|
|
|
@ -2308,14 +2308,6 @@
|
|||
*/
|
||||
//#define SENSORLESS_HOMING // StallGuard capable drivers only
|
||||
|
||||
/**
|
||||
* Use StallGuard2 to probe the bed with the nozzle.
|
||||
*
|
||||
* CAUTION: This could cause damage to machines that use a lead screw or threaded rod
|
||||
* to move the Z axis. Take extreme care when attempting to enable this feature.
|
||||
*/
|
||||
//#define SENSORLESS_PROBING // StallGuard capable drivers only
|
||||
|
||||
#if EITHER(SENSORLESS_HOMING, SENSORLESS_PROBING)
|
||||
// TMC2209: 0...255. TMC2130: -64...63
|
||||
#define X_STALL_SENSITIVITY 8
|
||||
|
|
Reference in a new issue