Fix temperature checking conditions (backwards!)

This commit is contained in:
Scott Lahteine 2016-03-30 04:13:13 -07:00
parent f0b96f5cae
commit 31450ad498

View file

@ -4260,7 +4260,7 @@ inline void gcode_M109() {
#define TEMP_CONDITIONS (residency_start_ms < 0 || now < residency_start_ms + (TEMP_RESIDENCY_TIME) * 1000UL) #define TEMP_CONDITIONS (residency_start_ms < 0 || now < residency_start_ms + (TEMP_RESIDENCY_TIME) * 1000UL)
#else #else
// Loop until the temperature is very close target // Loop until the temperature is very close target
#define TEMP_CONDITIONS (fabs(degHotend(target_extruder) - degTargetHotend(target_extruder)) < 0.75f) #define TEMP_CONDITIONS (isHeatingHotend(target_extruder))
#endif //TEMP_RESIDENCY_TIME #endif //TEMP_RESIDENCY_TIME
cancel_heatup = false; cancel_heatup = false;
@ -4320,7 +4320,7 @@ inline void gcode_M109() {
cancel_heatup = false; cancel_heatup = false;
millis_t now = millis(), next_temp_ms = now + 1000UL; millis_t now = millis(), next_temp_ms = now + 1000UL;
while (!cancel_heatup && fabs(degTargetBed() - degBed()) < 0.75f) { while (!cancel_heatup && isHeatingBed()) {
millis_t now = millis(); millis_t now = millis();
if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up. if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up.
next_temp_ms = now + 1000UL; next_temp_ms = now + 1000UL;