@ -821,23 +821,26 @@ void Planner::calculate_trapezoid_for_block(block_t* const block, const float &e
// POW((before->speed_x-after->speed_x), 2)+POW((before->speed_y-after->speed_y), 2));
//}
// The kernel called by recalculate() when scanning the plan from last to first entry.
void Planner::reverse_pass_kernel(block_t* const current, const block_t* const next) {
if (!current || !next) return;
if (current && next) {
// If entry speed is already at the maximum entry speed, no need to recheck. Block is cruising.
// If not, block in state of acceleration or deceleration. Reset entry speed to maximum and
// check for maximum allowable speed reductions to ensure maximum possible planned speed.
float max_entry_speed = current->max_entry_speed;
if (current->entry_speed != max_entry_speed) {
const float max_entry_speed = current->max_entry_speed;
if (current->entry_speed != max_entry_speed || TEST(next->flag, BLOCK_BIT_RECALCULATE)) {
// If nominal length true, max junction speed is guaranteed to be reached. Only compute
// for max allowable speed if block is decelerating and nominal length is false.
current->entry_speed = (TEST(current->flag, BLOCK_BIT_NOMINAL_LENGTH) || max_entry_speed <= next->entry_speed)
const float new_entry_speed = (TEST(current->flag, BLOCK_BIT_NOMINAL_LENGTH) || max_entry_speed <= next->entry_speed)
? max_entry_speed
: min(max_entry_speed, max_allowable_speed(-current->acceleration, next->entry_speed, current->millimeters));
if (new_entry_speed != current->entry_speed) {
current->entry_speed = new_entry_speed;
SBI(current->flag, BLOCK_BIT_RECALCULATE);
}
}
}
}
/**
* recalculate() needs to go over the current plan twice.
@ -845,7 +848,7 @@ void Planner::reverse_pass_kernel(block_t* const current, const block_t * const
*/
void Planner::reverse_pass() {
if (movesplanned() > 2) {
const uint8_t endnr = BLOCK_MOD(block_buffer_tail + 1); // tail is running. tail+1 shouldn't be altered because it's connected to the running block.
const uint8_t endnr = next_block_index(block_buffer_tail); // tail is running. tail+1 shouldn't be altered because it's connected to the running block.
uint8_t blocknr = prev_block_index(block_buffer_head);
block_t* current = &block_buffer[blocknr];
@ -854,11 +857,14 @@ void Planner::reverse_pass() {
if (current->entry_speed != max_entry_speed) {
// If nominal length true, max junction speed is guaranteed to be reached. Only compute
// for max allowable speed if block is decelerating and nominal length is false.
current->entry_speed = TEST(current->flag, BLOCK_BIT_NOMINAL_LENGTH)
const float new_entry_speed = TEST(current->flag, BLOCK_BIT_NOMINAL_LENGTH)
? max_entry_speed
: min(max_entry_speed, max_allowable_speed(-current->acceleration, MINIMUM_PLANNER_SPEED, current->millimeters));
if (current->entry_speed != new_entry_speed) {
current->entry_speed = new_entry_speed;
SBI(current->flag, BLOCK_BIT_RECALCULATE);
}
}
do {
const block_t * const next = current;
@ -871,24 +877,23 @@ void Planner::reverse_pass() {
// The kernel called by recalculate() when scanning the plan from first to last entry.
void Planner::forward_pass_kernel(const block_t* const previous, block_t* const current) {
if (!previous) return;
// If the previous block is an acceleration block, but it is not long enough to complete the
// full speed change within the block, we need to adjust the entry speed accordingly. Entry
// speeds have already been reset, maximized, and reverse planned by reverse planner.
// If nominal length is true, max junction speed is guaranteed to be reached. No need to recheck.
if (previous) {
// If the previous block is an acceleration block, too short to complete the full speed
// change, adjust the entry speed accordingly. Entry speeds have already been reset,
// maximized, and reverse-planned. If nominal length is set, max junction speed is
// guaranteed to be reached. No need to recheck.
if (!TEST(previous->flag, BLOCK_BIT_NOMINAL_LENGTH)) {
if (previous->entry_speed < current->entry_speed) {
float entry_speed = min(current->entry_speed,
max_allowable_speed(-previous->acceleration, previous->entry_speed, previous->millimeters));
const float new_entry_speed = min(current->entry_speed, max_allowable_speed(-previous->acceleration, previous->entry_speed, previous->millimeters));
// Check for junction speed change
if (current->entry_speed != entry_speed) {
current->entry_speed = entry_speed;
if (current->entry_speed != new_entry_speed) {
current->entry_speed = new_entry_speed;
SBI(current->flag, BLOCK_BIT_RECALCULATE);
}
}
}
}
}
/**
* recalculate() needs to go over the current plan twice.