Sanity check PIDTEMPBED plus BED_LIMIT_SWITCHING
This commit is contained in:
parent
8cb04816b5
commit
5955a3063f
3 changed files with 9 additions and 3 deletions
|
@ -131,10 +131,16 @@
|
|||
#error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Bed Heating Options - PID vs Limit Switching
|
||||
*/
|
||||
#if ENABLED(PIDTEMPBED) && ENABLED(BED_LIMIT_SWITCHING)
|
||||
#error To use BED_LIMIT_SWITCHING you must disable PIDTEMPBED.
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Mesh Bed Leveling
|
||||
*/
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
#if ENABLED(DELTA)
|
||||
#error MESH_BED_LEVELING does not yet support DELTA printers.
|
||||
|
|
|
@ -286,7 +286,7 @@
|
|||
// If this is enabled, find your own PID constants below.
|
||||
#define PIDTEMPBED
|
||||
|
||||
#define BED_LIMIT_SWITCHING
|
||||
//#define BED_LIMIT_SWITCHING
|
||||
|
||||
// This sets the max power delivered to the bed, and replaces the HEATER_BED_DUTY_CYCLE_DIVIDER option.
|
||||
// all forms of bed control obey this (PID, bang-bang, bang-bang with hysteresis)
|
||||
|
|
|
@ -745,7 +745,7 @@ void manage_heater() {
|
|||
soft_pwm_bed = 0;
|
||||
WRITE_HEATER_BED(LOW);
|
||||
}
|
||||
#else // BED_LIMIT_SWITCHING
|
||||
#else // !PIDTEMPBED && !BED_LIMIT_SWITCHING
|
||||
// Check if temperature is within the correct range
|
||||
if (current_temperature_bed > BED_MINTEMP && current_temperature_bed < BED_MAXTEMP) {
|
||||
soft_pwm_bed = current_temperature_bed < target_temperature_bed ? MAX_BED_POWER >> 1 : 0;
|
||||
|
|
Reference in a new issue