Spacing of g-codes in GCodes.md
This commit is contained in:
parent
fe912f44dc
commit
652d59cd80
1 changed files with 15 additions and 15 deletions
|
@ -2,12 +2,12 @@
|
||||||
|
|
||||||
### Movement G and M Codes
|
### Movement G and M Codes
|
||||||
```
|
```
|
||||||
G0 -> G1
|
G0 -> G1
|
||||||
G1 - Coordinated Movement X Y Z E
|
G1 - Coordinated Movement X Y Z E
|
||||||
G2 - CW ARC
|
G2 - CW ARC
|
||||||
G3 - CCW ARC
|
G3 - CCW ARC
|
||||||
G4 - Dwell S[seconds] or P[milliseconds]
|
G4 - Dwell S[seconds] or P[milliseconds]
|
||||||
G92 - Set current position to cordinates given
|
G92 - Set current position to cordinates given
|
||||||
M0 - Wait for user, with optional prompt message (to press the LCD button, requires ULTRA_LCD)
|
M0 - Wait for user, with optional prompt message (to press the LCD button, requires ULTRA_LCD)
|
||||||
M0 Click When Ready ; show "Click When Ready" until the button is pressed.
|
M0 Click When Ready ; show "Click When Ready" until the button is pressed.
|
||||||
M1 - Same as M0
|
M1 - Same as M0
|
||||||
|
@ -94,8 +94,8 @@ M600 - Pause for filament change X<xpos> Y<ypos> Z<lift> E<initial retract> L<la
|
||||||
```
|
```
|
||||||
### Units and Measures G and M Codes
|
### Units and Measures G and M Codes
|
||||||
```
|
```
|
||||||
G90 - Use Absolute Coordinates
|
G90 - Use Absolute Coordinates
|
||||||
G91 - Use Relative Coordinates
|
G91 - Use Relative Coordinates
|
||||||
M82 - Set E codes absolute (default)
|
M82 - Set E codes absolute (default)
|
||||||
M83 - Set E codes relative while in Absolute Coordinates (G90) mode
|
M83 - Set E codes relative while in Absolute Coordinates (G90) mode
|
||||||
M92 - Set axis_steps_per_unit - same syntax as G92
|
M92 - Set axis_steps_per_unit - same syntax as G92
|
||||||
|
@ -112,19 +112,19 @@ M221 - Set extrude factor override percentage: S<factor in percent>
|
||||||
```
|
```
|
||||||
### Firmware Retraction G and M Codes
|
### Firmware Retraction G and M Codes
|
||||||
```
|
```
|
||||||
G10 - Retract filament according to settings of M207
|
G10 - Retract filament according to settings of M207
|
||||||
G11 - Retract recover filament according to settings of M208
|
G11 - Retract recover filament according to settings of M208
|
||||||
M207 - Set retract length S[positive mm] F[feedrate mm/min] Z[additional zlift/hop], stays in mm regardless of M200 setting
|
M207 - Set retract length S[positive mm] F[feedrate mm/min] Z[additional zlift/hop], stays in mm regardless of M200 setting
|
||||||
M208 - Set recover=unretract length S[positive mm surplus to the M207 S*] F[feedrate mm/s]
|
M208 - Set recover=unretract length S[positive mm surplus to the M207 S*] F[feedrate mm/s]
|
||||||
M209 - S<1=true/0=false> enable automatic retract detect if the slicer did not support G10/11: every normal extrude-only move will be classified as retract depending on the direction
|
M209 - S<1=true/0=false> enable automatic retract detect if the slicer did not support G10/11: every normal extrude-only move will be classified as retract depending on the direction
|
||||||
```
|
```
|
||||||
### Z Probe G and M Codes
|
### Z Probe G and M Codes
|
||||||
```
|
```
|
||||||
G28 - Home all Axis
|
G28 - Home all Axis
|
||||||
G29 - Detailed Z-Probe, probes the bed at 3 or more points. The printer must be homed with G28 before G29.
|
G29 - Detailed Z-Probe, probes the bed at 3 or more points. The printer must be homed with G28 before G29.
|
||||||
G30 - Single Z Probe, probes bed at current XY location.
|
G30 - Single Z Probe, probes bed at current XY location.
|
||||||
G31 - Dock Z Probe sled (if enabled)
|
G31 - Dock Z Probe sled (if enabled)
|
||||||
G32 - Undock Z Probe sled (if enabled)
|
G32 - Undock Z Probe sled (if enabled)
|
||||||
M48 - Measure Z_Probe repeatability: P<points> X<xpos> Y<ypos> V<verbosity> E=engage L<legs of travel>
|
M48 - Measure Z_Probe repeatability: P<points> X<xpos> Y<ypos> V<verbosity> E=engage L<legs of travel>
|
||||||
As with G29, the E flag causes the probe to stow after each probe.
|
As with G29, the E flag causes the probe to stow after each probe.
|
||||||
M401 - Lower Z-probe (if present)
|
M401 - Lower Z-probe (if present)
|
||||||
|
|
Reference in a new issue