Include bed hysteresis setting in the example configs
This commit is contained in:
parent
178aeb79c8
commit
69c00aea4c
19 changed files with 110 additions and 19 deletions
|
@ -192,11 +192,12 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109/M190 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -195,11 +195,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -199,11 +199,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
//#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
//#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -217,11 +217,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 3 // (seconds)
|
#define TEMP_RESIDENCY_TIME 3 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 2 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 2 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -195,11 +195,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -198,11 +198,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -215,11 +215,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|
|
@ -192,11 +192,16 @@
|
||||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||||
|
|
||||||
// Actual temperature must be close to target for this long before M109 returns success
|
// Extruder temperature must be close to target for this long before M109 returns success
|
||||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
|
// Bed temperature must be close to target for this long before M190 returns success
|
||||||
|
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||||
|
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||||
|
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||||
|
|
||||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||||
// to check that the wiring to the thermistor is not broken.
|
// to check that the wiring to the thermistor is not broken.
|
||||||
// Otherwise this would lead to the heater being powered on all the time.
|
// Otherwise this would lead to the heater being powered on all the time.
|
||||||
|
|