Long thermistor tables need special consideration
This commit is contained in:
parent
a4f9c3373f
commit
853a9056ac
2 changed files with 13 additions and 8 deletions
|
@ -54,10 +54,10 @@
|
|||
#if HOTEND_USES_THERMISTOR
|
||||
#if ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
|
||||
static void* heater_ttbl_map[2] = { (void*)HEATER_0_TEMPTABLE, (void*)HEATER_1_TEMPTABLE };
|
||||
static uint8_t heater_ttbllen_map[2] = { HEATER_0_TEMPTABLE_LEN, HEATER_1_TEMPTABLE_LEN };
|
||||
static constexpr uint8_t heater_ttbllen_map[2] = { HEATER_0_TEMPTABLE_LEN, HEATER_1_TEMPTABLE_LEN };
|
||||
#else
|
||||
static void* heater_ttbl_map[HOTENDS] = ARRAY_BY_HOTENDS((void*)HEATER_0_TEMPTABLE, (void*)HEATER_1_TEMPTABLE, (void*)HEATER_2_TEMPTABLE, (void*)HEATER_3_TEMPTABLE, (void*)HEATER_4_TEMPTABLE);
|
||||
static uint8_t heater_ttbllen_map[HOTENDS] = ARRAY_BY_HOTENDS(HEATER_0_TEMPTABLE_LEN, HEATER_1_TEMPTABLE_LEN, HEATER_2_TEMPTABLE_LEN, HEATER_3_TEMPTABLE_LEN, HEATER_4_TEMPTABLE_LEN);
|
||||
static constexpr uint8_t heater_ttbllen_map[HOTENDS] = ARRAY_BY_HOTENDS(HEATER_0_TEMPTABLE_LEN, HEATER_1_TEMPTABLE_LEN, HEATER_2_TEMPTABLE_LEN, HEATER_3_TEMPTABLE_LEN, HEATER_4_TEMPTABLE_LEN);
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
|
|
@ -184,21 +184,26 @@
|
|||
#ifdef THERMISTORBED
|
||||
#define BEDTEMPTABLE TT_NAME(THERMISTORBED)
|
||||
#define BEDTEMPTABLE_LEN COUNT(BEDTEMPTABLE)
|
||||
#elif defined(HEATER_BED_USES_THERMISTOR)
|
||||
#error "No bed thermistor table specified"
|
||||
#else
|
||||
#ifdef HEATER_BED_USES_THERMISTOR
|
||||
#error "No bed thermistor table specified"
|
||||
#endif
|
||||
#define BEDTEMPTABLE_LEN 0
|
||||
#endif
|
||||
|
||||
#ifdef THERMISTORCHAMBER
|
||||
#define CHAMBERTEMPTABLE TT_NAME(THERMISTORCHAMBER)
|
||||
#define CHAMBERTEMPTABLE_LEN COUNT(CHAMBERTEMPTABLE)
|
||||
#elif defined(HEATER_CHAMBER_USES_THERMISTOR)
|
||||
#error "No chamber thermistor table specified"
|
||||
#else
|
||||
#ifdef HEATER_CHAMBER_USES_THERMISTOR
|
||||
#error "No chamber thermistor table specified"
|
||||
#endif
|
||||
#define CHAMBERTEMPTABLE_LEN 0
|
||||
#endif
|
||||
|
||||
// The SCAN_THERMISTOR_TABLE macro needs alteration?
|
||||
static_assert(HEATER_0_TEMPTABLE_LEN < 128 && HEATER_1_TEMPTABLE_LEN < 128 && HEATER_2_TEMPTABLE_LEN < 128 && HEATER_3_TEMPTABLE_LEN < 128 && HEATER_4_TEMPTABLE_LEN < 128 && BEDTEMPTABLE_LEN < 128 && CHAMBERTEMPTABLE_LEN < 128,
|
||||
"Temperature conversion tables over 127 entries need special consideration."
|
||||
);
|
||||
|
||||
// Set the high and low raw values for the heaters
|
||||
// For thermistors the highest temperature results in the lowest ADC value
|
||||
// For thermocouples the highest temperature results in the highest ADC value
|
||||
|
|
Reference in a new issue