Move Job Recovery Menu to its own file

This commit is contained in:
Scott Lahteine 2018-10-27 22:48:28 -05:00
parent 9f11e0284c
commit 9cd5471202
3 changed files with 111 additions and 88 deletions

View file

@ -19,14 +19,12 @@
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
#pragma once
/**
* power_loss_recovery.h - Resume an SD print after power-loss
*/
#ifndef _POWER_LOSS_RECOVERY_H_
#define _POWER_LOSS_RECOVERY_H_
#include "../sd/cardreader.h"
#include "../core/millis_t.h"
#include "../inc/MarlinConfigPre.h"
@ -99,5 +97,3 @@ extern uint8_t job_recovery_commands_count;
void check_print_job_recovery();
void save_job_recovery_info();
#endif // _POWER_LOSS_RECOVERY_H_

View file

@ -27,7 +27,6 @@
#include "menu.h"
#include "../ultralcd.h"
#include "../../sd/cardreader.h"
#include "../../module/planner.h"
#include "../../module/motion.h"
#include "../../module/probe.h"
@ -40,18 +39,14 @@
#include <stdarg.h>
#if ENABLED(SDSUPPORT)
#include "../../sd/cardreader.h"
#endif
#if ENABLED(ADVANCED_PAUSE_FEATURE)
#include "../../feature/pause.h"
#endif
#if ENABLED(POWER_LOSS_RECOVERY)
#include "../../feature/power_loss_recovery.h"
#endif
#if ENABLED(PRINTCOUNTER) && ENABLED(LCD_INFO_MENU)
#include "../../libs/duration_t.h"
#endif
#if HAS_LEVELING
#include "../../feature/bedlevel/bedlevel.h"
#endif
@ -405,80 +400,6 @@ void line_to_z(const float &z) {
line_to_current_z();
}
#if ENABLED(POWER_LOSS_RECOVERY)
static void lcd_power_loss_recovery_resume() {
char cmd[20];
// Return to status now
lcd_return_to_status();
// Turn leveling off and home
enqueue_and_echo_commands_P(PSTR("M420 S0\nG28 R0"
#if ENABLED(MARLIN_DEV_MODE)
" S"
#elif !IS_KINEMATIC
" X Y"
#endif
));
#if HAS_HEATED_BED
const int16_t bt = job_recovery_info.target_temperature_bed;
if (bt) {
// Restore the bed temperature
sprintf_P(cmd, PSTR("M190 S%i"), bt);
enqueue_and_echo_command(cmd);
}
#endif
// Restore all hotend temperatures
HOTEND_LOOP() {
const int16_t et = job_recovery_info.target_temperature[e];
if (et) {
#if HOTENDS > 1
sprintf_P(cmd, PSTR("T%i"), e);
enqueue_and_echo_command(cmd);
#endif
sprintf_P(cmd, PSTR("M109 S%i"), et);
enqueue_and_echo_command(cmd);
}
}
#if HOTENDS > 1
sprintf_P(cmd, PSTR("T%i"), job_recovery_info.active_hotend);
enqueue_and_echo_command(cmd);
#endif
// Restore print cooling fan speeds
for (uint8_t i = 0; i < FAN_COUNT; i++) {
uint8_t f = job_recovery_info.fan_speed[i];
if (f) {
sprintf_P(cmd, PSTR("M106 P%i S%i"), i, f);
enqueue_and_echo_command(cmd);
}
}
// Start draining the job recovery command queue
job_recovery_phase = JOB_RECOVERY_YES;
}
static void lcd_power_loss_recovery_cancel() {
card.removeJobRecoveryFile();
card.autostart_index = 0;
lcd_return_to_status();
}
void menu_job_recovery() {
defer_return_to_status = true;
START_MENU();
STATIC_ITEM(MSG_POWER_LOSS_RECOVERY);
MENU_ITEM(function, MSG_RESUME_PRINT, lcd_power_loss_recovery_resume);
MENU_ITEM(function, MSG_STOP_PRINT, lcd_power_loss_recovery_cancel);
END_MENU();
}
#endif // POWER_LOSS_RECOVERY
#if ENABLED(CUSTOM_USER_MENUS)
#ifdef USER_SCRIPT_DONE

View file

@ -0,0 +1,106 @@
/**
* Marlin 3D Printer Firmware
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
//
// Job Recovery Menu
//
#include "../../inc/MarlinConfigPre.h"
#if HAS_LCD_MENU && ENABLED(POWER_LOSS_RECOVERY)
#include "menu.h"
#include "../../gcode/queue.h"
#include "../../sd/cardreader.h"
#include "../../feature/power_loss_recovery.h"
static void lcd_power_loss_recovery_resume() {
char cmd[20];
// Return to status now
lcd_return_to_status();
// Turn leveling off and home
enqueue_and_echo_commands_P(PSTR("M420 S0\nG28 R0"
#if ENABLED(MARLIN_DEV_MODE)
" S"
#elif !IS_KINEMATIC
" X Y"
#endif
));
#if HAS_HEATED_BED
const int16_t bt = job_recovery_info.target_temperature_bed;
if (bt) {
// Restore the bed temperature
sprintf_P(cmd, PSTR("M190 S%i"), bt);
enqueue_and_echo_command(cmd);
}
#endif
// Restore all hotend temperatures
HOTEND_LOOP() {
const int16_t et = job_recovery_info.target_temperature[e];
if (et) {
#if HOTENDS > 1
sprintf_P(cmd, PSTR("T%i"), e);
enqueue_and_echo_command(cmd);
#endif
sprintf_P(cmd, PSTR("M109 S%i"), et);
enqueue_and_echo_command(cmd);
}
}
#if HOTENDS > 1
sprintf_P(cmd, PSTR("T%i"), job_recovery_info.active_hotend);
enqueue_and_echo_command(cmd);
#endif
// Restore print cooling fan speeds
for (uint8_t i = 0; i < FAN_COUNT; i++) {
uint8_t f = job_recovery_info.fan_speed[i];
if (f) {
sprintf_P(cmd, PSTR("M106 P%i S%i"), i, f);
enqueue_and_echo_command(cmd);
}
}
// Start draining the job recovery command queue
job_recovery_phase = JOB_RECOVERY_YES;
}
static void lcd_power_loss_recovery_cancel() {
card.removeJobRecoveryFile();
card.autostart_index = 0;
lcd_return_to_status();
}
void menu_job_recovery() {
defer_return_to_status = true;
START_MENU();
STATIC_ITEM(MSG_POWER_LOSS_RECOVERY);
MENU_ITEM(function, MSG_RESUME_PRINT, lcd_power_loss_recovery_resume);
MENU_ITEM(function, MSG_STOP_PRINT, lcd_power_loss_recovery_cancel);
END_MENU();
}
#endif // HAS_LCD_MENU && POWER_LOSS_RECOVERY