Added option 'H' to G29 P4.
- Added `H` to set a nozzle height adjustment to surface of the bed. - Updated G29 P4 comments to reflect changes.
This commit is contained in:
parent
e687782875
commit
a1632cfa0a
2 changed files with 122 additions and 127 deletions
|
@ -115,7 +115,7 @@
|
|||
#endif
|
||||
|
||||
static float measure_point_with_encoder();
|
||||
static float measure_business_card_thickness(float&);
|
||||
static float measure_business_card_thickness(float);
|
||||
static bool g29_parameter_parsing();
|
||||
static void find_mean_mesh_height();
|
||||
static void shift_mesh_height();
|
||||
|
|
|
@ -84,25 +84,23 @@
|
|||
*
|
||||
* A Activate Activate the Unified Bed Leveling system.
|
||||
*
|
||||
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem. This is invoked as
|
||||
* G29 P2 B. The mode of G29 P2 allows you to use a business card or recipe card
|
||||
* as a shim that the nozzle will pinch as it is lowered. The idea is that you
|
||||
* can easily feel the nozzle getting to the same height by the amount of resistance
|
||||
* the business card exhibits to movement. You should try to achieve the same amount
|
||||
* of resistance on each probed point to facilitate accurate and repeatable measurements.
|
||||
* You should be very careful not to drive the nozzle into the business card with a
|
||||
* lot of force as it is very possible to cause damage to your printer if your are
|
||||
* careless. If you use the B option with G29 P2 B you can omit the numeric value
|
||||
* on first use to measure the business card's thickness. Subsequent usage of 'B'
|
||||
* will apply the previously-measured thickness as the default.
|
||||
* Note: A non-compressible Spark Gap feeler gauge is recommended over a Business Card.
|
||||
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem with P2.
|
||||
* Note: A non-compressible Spark Gap feeler gauge is recommended over a business card.
|
||||
* In this mode of G29 P2, a business or index card is used as a shim that the nozzle can
|
||||
* grab onto as it is lowered. In principle, the nozzle-bed distance is the same when the
|
||||
* same resistance is felt in the shim. You can omit the numerical value on first invocation
|
||||
* of G29 P2 B to measure shim thickness. Subsequent use of 'B' will apply the previously-
|
||||
* measured thickness by default.
|
||||
*
|
||||
* C Continue Continue, Constant, Current Location. This is not a primary command. C is used to
|
||||
* further refine the behaviour of several other commands. Issuing a G29 P1 C will
|
||||
* continue the generation of a partially constructed Mesh without invalidating what has
|
||||
* been done. Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current
|
||||
* location in its search for the closest unmeasured Mesh Point. When used with a G29 Z C
|
||||
* it indicates to use the current location instead of defaulting to the center of the print bed.
|
||||
* C Continue G29 P1 C continues the generation of a partially-constructed Mesh without invalidating
|
||||
* previous measurements.
|
||||
*
|
||||
* C Constant G29 P2 C specifies a Constant and tells the Manual Probe subsystem to use the current
|
||||
* location in its search for the closest unmeasured Mesh Point.
|
||||
*
|
||||
* G29 P3 C specifies the Constant for the fill. Otherwise, uses a "reasonable" value.
|
||||
*
|
||||
* C Current G29 Z C uses the Current location (instead of bed center or nearest edge).
|
||||
*
|
||||
* D Disable Disable the Unified Bed Leveling system.
|
||||
*
|
||||
|
@ -112,17 +110,18 @@
|
|||
* specified height, no correction is applied and natural printer kenimatics take over. If no
|
||||
* number is specified for the command, 10mm is assumed to be reasonable.
|
||||
*
|
||||
* H # Height Specify the Height to raise the nozzle after each manual probe of the bed. The
|
||||
* default is 5mm.
|
||||
* H # Height With P2, 'H' specifies the Height to raise the nozzle after each manual probe of the bed.
|
||||
* If omitted, the nozzle will raise by Z_CLEARANCE_BETWEEN_PROBES.
|
||||
*
|
||||
* I # Invalidate Invalidate specified number of Mesh Points. The nozzle location is used unless
|
||||
* the X and Y parameter are used. If no number is specified, only the closest Mesh
|
||||
* point to the location is invalidated. The 'T' parameter is also available to produce
|
||||
* a map after the operation. This command is useful to invalidate a portion of the
|
||||
* Mesh so it can be adjusted using other tools in the Unified Bed Leveling System. When
|
||||
* attempting to invalidate an isolated bad point in the mesh, the 'T' option will indicate
|
||||
* where the nozzle is positioned in the Mesh with (#). You can move the nozzle around on
|
||||
* the bed and use this feature to select the center of the area (or cell) you want to
|
||||
* H # Offset With P4, 'H' specifies the Offset above the mesh height to place the nozzle.
|
||||
* If omitted, Z_CLEARANCE_BETWEEN_PROBES will be used.
|
||||
*
|
||||
* I # Invalidate Invalidate the specified number of Mesh Points near the given 'X' 'Y'. If X or Y are omitted,
|
||||
* the nozzle location is used. If no 'I' value is given, only the point nearest to the location
|
||||
* is invalidated. Use 'T' to produce a map afterward. This command is useful to invalidate a
|
||||
* portion of the Mesh so it can be adjusted using other UBL tools. When attempting to invalidate
|
||||
* an isolated bad mesh point, the 'T' option shows the nozzle position in the Mesh with (#). You
|
||||
* can move the nozzle around and use this feature to select the center of the area (or cell) to
|
||||
* invalidate.
|
||||
*
|
||||
* J # Grid Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side.
|
||||
|
@ -151,95 +150,81 @@
|
|||
* area cannot be automatically probed. For Delta printers the area in which DELTA_PROBEABLE_RADIUS
|
||||
* and DELTA_PRINTABLE_RADIUS do not overlap will not be automatically probed.
|
||||
*
|
||||
* These points will be handled in Phase 2 and Phase 3. If the Phase 1 command is given the
|
||||
* C (Continue) parameter it does not invalidate the Mesh prior to automatically
|
||||
* probing needed locations. This allows you to invalidate portions of the Mesh but still
|
||||
* use the automatic probing capabilities of the Unified Bed Leveling System. An X and Y
|
||||
* parameter can be given to prioritize where the command should be trying to measure points.
|
||||
* If the X and Y parameters are not specified the current probe position is used.
|
||||
* P1 accepts a 'T' (Topology) parameter so you can observe mesh generation.
|
||||
* P1 also watches for the LCD Panel Encoder Switch to be held down (assuming you have one),
|
||||
* and will suspend generation of the Mesh in that case. (Note: This check is only done
|
||||
* between probe points, so you must press and hold the switch until the Phase 1 command
|
||||
* detects it.)
|
||||
* Unreachable points will be handled in Phase 2 and Phase 3.
|
||||
*
|
||||
* P2 Phase 2 Probe areas of the Mesh that can't be automatically handled. Phase 2 respects an H
|
||||
* parameter to control the height between Mesh points. The default height for movement
|
||||
* between Mesh points is 5mm. A smaller number can be used to make this part of the
|
||||
* calibration less time consuming. You will be running the nozzle down until it just barely
|
||||
* touches the glass. You should have the nozzle clean with no plastic obstructing your view.
|
||||
* Use caution and move slowly. It is possible to damage your printer if you are careless.
|
||||
* Note that this command will use the configuration #define SIZE_OF_LITTLE_RAISE if the
|
||||
* nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED.
|
||||
* Use 'C' to leave the previous mesh intact and automatically probe needed points. This allows you
|
||||
* to invalidate parts of the Mesh but still use Automatic Probing.
|
||||
*
|
||||
* The H parameter can be set negative if your Mesh dips in a large area. You can press
|
||||
* and hold the LCD Panel's encoder wheel to terminate the current Phase 2 command. You
|
||||
* can then re-issue the G29 P 2 command with an H parameter that is more suitable for the
|
||||
* area you are manually probing. Note that the command tries to start you in a corner
|
||||
* of the bed where movement will be predictable. You can force the location to be used in
|
||||
* the distance calculations by using the X and Y parameters. You may find it is helpful to
|
||||
* print out a Mesh Map (G29 T) to understand where the mesh is invalidated and where
|
||||
* the nozzle will need to move in order to complete the command. The C parameter is
|
||||
* available on the Phase 2 command also and indicates the search for points to measure should
|
||||
* be done based on the current location of the nozzle.
|
||||
* The 'X' and 'Y' parameters prioritize where to try and measure points. If omitted, the current
|
||||
* probe position is used.
|
||||
*
|
||||
* A B parameter is also available for this command and described up above. It places the
|
||||
* manual probe subsystem into Business Card mode where the thickness of a business card is
|
||||
* measured and then used to accurately set the nozzle height in all manual probing for the
|
||||
* duration of the command. (S for Shim mode would be a better parameter name, but S is needed
|
||||
* for Save or Store of the Mesh to EEPROM) A Business card can be used, but you will have
|
||||
* better results if you use a flexible Shim that does not compress very much. That makes it
|
||||
* easier for you to get the nozzle to press with similar amounts of force against the shim so you
|
||||
* can get accurate measurements. As you are starting to touch the nozzle against the shim try
|
||||
* to get it to grasp the shim with the same force as when you measured the thickness of the
|
||||
* shim at the start of the command.
|
||||
* Use 'T' (Topology) to generate a report of mesh generation.
|
||||
*
|
||||
* Phase 2 allows the T (Map) parameter to be specified. This helps the user see the progression
|
||||
* of the Mesh being built.
|
||||
* P1 will suspend Mesh generation if the controller button is held down. Note that you may need
|
||||
* to press and hold the switch for several seconds if moves are underway.
|
||||
*
|
||||
* NOTE: P2 is not available unless you have LCD support enabled!
|
||||
* P2 Phase 2 Probe unreachable points.
|
||||
*
|
||||
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths the
|
||||
* user can go down. If the user specifies the value using the C parameter, the closest invalid
|
||||
* mesh points to the nozzle will be filled. The user can specify a repeat count using the R
|
||||
* parameter with the C version of the command.
|
||||
* Use 'H' to set the height between Mesh points. If omitted, Z_CLEARANCE_BETWEEN_PROBES is used.
|
||||
* Smaller values will be quicker. Move the nozzle down till it barely touches the bed. Make sure the
|
||||
* nozzle is clean and unobstructed. Use caution and move slowly. This can damage your printer!
|
||||
* (Uses SIZE_OF_LITTLE_RAISE mm if the nozzle is moving less than BIG_RAISE_NOT_NEEDED mm.)
|
||||
*
|
||||
* A second version of the fill command is available if no C constant is specified. Not
|
||||
* specifying a C constant will invoke the 'Smart Fill' algorithm. The G29 P3 command will search
|
||||
* from the edges of the mesh inward looking for invalid mesh points. It will look at the next
|
||||
* several mesh points to determine if the print bed is sloped up or down. If the bed is sloped
|
||||
* upward from the invalid mesh point, it will be replaced with the value of the nearest mesh point.
|
||||
* If the bed is sloped downward from the invalid mesh point, it will be replaced with a value that
|
||||
* puts all three points in a line. The second version of the G29 P3 command is a quick, easy and
|
||||
* usually safe way to populate the unprobed regions of your mesh so you can continue to the G26
|
||||
* Mesh Validation Pattern phase. Please note that you are populating your mesh with unverified
|
||||
* numbers. You should use some scrutiny and caution.
|
||||
* The 'H' value can be negative if the Mesh dips in a large area. Press and hold the
|
||||
* controller button to terminate the current Phase 2 command. You can then re-issue "G29 P 2"
|
||||
* with an 'H' parameter more suitable for the area you're manually probing. Note that the command
|
||||
* tries to start in a corner of the bed where movement will be predictable. Override the distance
|
||||
* calculation location with the X and Y parameters. You can print a Mesh Map (G29 T) to see where
|
||||
* the mesh is invalidated and where the nozzle needs to move to complete the command. Use 'C' to
|
||||
* indicate that the search should be based on the current position.
|
||||
*
|
||||
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assume the existence of
|
||||
* an LCD Panel. It is possible to fine tune the mesh without the use of an LCD Panel using
|
||||
* G42 and M421; see the UBL documentation for further details.
|
||||
* The 'B' parameter for this command is described above. It places the manual probe subsystem into
|
||||
* Business Card mode where the thickness of a business card is measured and then used to accurately
|
||||
* set the nozzle height in all manual probing for the duration of the command. A Business card can
|
||||
* be used, but you'll get better results with a flexible Shim that doesn't compress. This makes it
|
||||
* easier to produce similar amounts of force and get more accurate measurements. Google if you're
|
||||
* not sure how to use a shim.
|
||||
*
|
||||
* The System will search for the closest Mesh Point to the nozzle. It will move the
|
||||
* nozzle to this location. The user can use the LCD Panel to carefully adjust the nozzle
|
||||
* so it is just barely touching the bed. When the user clicks the control, the System
|
||||
* will lock in that height for that point in the Mesh Compensation System.
|
||||
* The 'T' (Map) parameter helps track Mesh building progress.
|
||||
*
|
||||
* Phase 4 has several additional parameters that the user may find helpful. Phase 4
|
||||
* can be started at a specific location by specifying an X and Y parameter. Phase 4
|
||||
* can be requested to continue the adjustment of Mesh Points by using the R(epeat)
|
||||
* parameter. If the Repetition count is not specified, it is assumed the user wishes
|
||||
* to adjust the entire matrix. The nozzle is moved to the Mesh Point being edited.
|
||||
* The command can be terminated early (or after the area of interest has been edited) by
|
||||
* pressing and holding the encoder wheel until the system recognizes the exit request.
|
||||
* Phase 4's general form is G29 P4 [R # of points] [X position] [Y position]
|
||||
* NOTE: P2 requires an LCD controller!
|
||||
*
|
||||
* Phase 4 is intended to be used with the G26 Mesh Validation Command. Using the
|
||||
* information left on the printer's bed from the G26 command it is very straight forward
|
||||
* and easy to fine tune the Mesh. One concept that is important to remember and that
|
||||
* will make using the Phase 4 command easy to use is this: You are editing the Mesh Points.
|
||||
* If you have too little clearance and not much plastic was extruded in an area, you want to
|
||||
* LOWER the Mesh Point at the location. If you did not get good adheasion, you want to
|
||||
* RAISE the Mesh Point at that location.
|
||||
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths to
|
||||
* go down:
|
||||
*
|
||||
* - If a 'C' constant is specified, the closest invalid mesh points to the nozzle will be filled,
|
||||
* and a repeat count can then also be specified with 'R'.
|
||||
*
|
||||
* - Leaving out 'C' invokes Smart Fill, which scans the mesh from the edges inward looking for
|
||||
* invalid mesh points. Adjacent points are used to determine the bed slope. If the bed is sloped
|
||||
* upward from the invalid point, it takes the value of the nearest point. If sloped downward, it's
|
||||
* replaced by a value that puts all three points in a line. This version of G29 P3 is a quick, easy
|
||||
* and (usually) safe way to populate unprobed mesh regions before continuing to G26 Mesh Validation
|
||||
* Pattern. Note that this populates the mesh with unverified values. Pay attention and use caution.
|
||||
*
|
||||
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assumes the existence of
|
||||
* an LCD Panel. It is possible to fine tune the mesh without an LCD Panel using
|
||||
* G42 and M421. See the UBL documentation for further details.
|
||||
*
|
||||
* Phase 4 is meant to be used with G26 Mesh Validation to fine tune the mesh by direct editing
|
||||
* of Mesh Points. Raise and lower points to fine tune the mesh until it gives consistently reliable
|
||||
* adhesion.
|
||||
*
|
||||
* P4 moves to the closest Mesh Point (and/or the given X Y), raises the nozzle above the mesh height
|
||||
* by the given 'H' offset (or default Z_CLEARANCE_BETWEEN_PROBES), and waits while the controller is
|
||||
* used to adjust the nozzle height. On click the displayed height is saved in the mesh.
|
||||
*
|
||||
* Start Phase 4 at a specific location with X and Y. Adjust a specific number of Mesh Points with
|
||||
* the 'R' (Repeat) parameter. (If 'R' is left out, the whole matrix is assumed.) This command can be
|
||||
* terminated early (e.g., after editing the area of interest) by pressing and holding the encoder button.
|
||||
*
|
||||
* The general form is G29 P4 [R points] [X position] [Y position]
|
||||
*
|
||||
* The H [offset] parameter is useful if a shim is used to fine-tune the mesh. For a 0.4mm shim the
|
||||
* command would be G29 P4 H0.4. The nozzle is moved to the shim height, you adjust height to the shim,
|
||||
* and on click the height minus the shim thickness will be saved in the mesh.
|
||||
*
|
||||
* !!Use with caution, as a very poor mesh could cause the nozzle to crash into the bed!!
|
||||
*
|
||||
* NOTE: P4 is not available unless you have LCD support enabled!
|
||||
*
|
||||
|
@ -494,28 +479,29 @@
|
|||
g29_y_pos = current_position[Y_AXIS];
|
||||
}
|
||||
|
||||
float height = Z_CLEARANCE_BETWEEN_PROBES;
|
||||
|
||||
if (parser.seen('B')) {
|
||||
g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(height);
|
||||
g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(Z_CLEARANCE_BETWEEN_PROBES);
|
||||
if (FABS(g29_card_thickness) > 1.5) {
|
||||
SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement.");
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
if (parser.seen('H') && parser.has_value()) height = parser.value_float();
|
||||
|
||||
if (!position_is_reachable_xy(g29_x_pos, g29_y_pos)) {
|
||||
SERIAL_PROTOCOLLNPGM("XY outside printable radius.");
|
||||
return;
|
||||
}
|
||||
|
||||
const float height = parser.seen('H') && parser.has_value() ? parser.value_float() : Z_CLEARANCE_BETWEEN_PROBES;
|
||||
manually_probe_remaining_mesh(g29_x_pos, g29_y_pos, height, g29_card_thickness, parser.seen('T'));
|
||||
|
||||
SERIAL_PROTOCOLLNPGM("G29 P2 finished.");
|
||||
|
||||
#else
|
||||
|
||||
SERIAL_PROTOCOLLNPGM("?P2 is only available when an LCD is present.");
|
||||
return;
|
||||
|
||||
#endif
|
||||
} break;
|
||||
|
||||
|
@ -537,19 +523,17 @@
|
|||
if (location.x_index < 0) {
|
||||
// No more REACHABLE INVALID mesh points to populate, so we ASSUME
|
||||
// user meant to populate ALL INVALID mesh points to value
|
||||
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) {
|
||||
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) {
|
||||
if ( isnan(z_values[x][y])) {
|
||||
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
||||
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
||||
if (isnan(z_values[x][y]))
|
||||
z_values[x][y] = g29_constant;
|
||||
}
|
||||
}
|
||||
}
|
||||
break; // No more invalid Mesh Points to populate
|
||||
}
|
||||
z_values[location.x_index][location.y_index] = g29_constant;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
}
|
||||
else {
|
||||
const float cvf = parser.value_float();
|
||||
switch((int)truncf(cvf * 10.0) - 30) { // 3.1 -> 1
|
||||
#if ENABLED(UBL_G29_P31)
|
||||
|
@ -967,7 +951,7 @@
|
|||
|
||||
static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); }
|
||||
|
||||
float unified_bed_leveling::measure_business_card_thickness(float &in_height) {
|
||||
float unified_bed_leveling::measure_business_card_thickness(float in_height) {
|
||||
has_control_of_lcd_panel = true;
|
||||
save_ubl_active_state_and_disable(); // Disable bed level correction for probing
|
||||
|
||||
|
@ -1466,12 +1450,21 @@
|
|||
}
|
||||
|
||||
#if ENABLED(NEWPANEL)
|
||||
|
||||
void unified_bed_leveling::fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) {
|
||||
if (!parser.seen('R')) // fine_tune_mesh() is special. If no repetition count flag is specified
|
||||
g29_repetition_cnt = 1; // do exactly one mesh location. Otherwise use what the parser decided.
|
||||
|
||||
|
||||
#if ENABLED(UBL_MESH_EDIT_MOVES_Z)
|
||||
const bool is_offset = parser.seen('H');
|
||||
const float h_offset = is_offset ? parser.value_linear_units() : Z_CLEARANCE_BETWEEN_PROBES;
|
||||
if (is_offset && !WITHIN(h_offset, 0, 10)) {
|
||||
SERIAL_PROTOCOLLNPGM("Offset out of bounds. (0 to 10mm)\n");
|
||||
return;
|
||||
}
|
||||
#endif
|
||||
|
||||
mesh_index_pair location;
|
||||
uint16_t not_done[16];
|
||||
|
||||
if (!position_is_reachable_xy(lx, ly)) {
|
||||
SERIAL_PROTOCOLLNPGM("(X,Y) outside printable radius.");
|
||||
|
@ -1480,12 +1473,13 @@
|
|||
|
||||
save_ubl_active_state_and_disable();
|
||||
|
||||
memset(not_done, 0xFF, sizeof(not_done));
|
||||
|
||||
LCD_MESSAGEPGM(MSG_UBL_FINE_TUNE_MESH);
|
||||
|
||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
||||
do_blocking_move_to_xy(lx, ly);
|
||||
|
||||
uint16_t not_done[16];
|
||||
memset(not_done, 0xFF, sizeof(not_done));
|
||||
do {
|
||||
location = find_closest_mesh_point_of_type(SET_IN_BITMAP, lx, ly, USE_NOZZLE_AS_REFERENCE, not_done, false);
|
||||
|
||||
|
@ -1521,8 +1515,8 @@
|
|||
|
||||
do {
|
||||
new_z = lcd_mesh_edit();
|
||||
#ifdef UBL_MESH_EDIT_MOVES_Z
|
||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES + new_z); // Move the nozzle as the point is edited
|
||||
#if ENABLED(UBL_MESH_EDIT_MOVES_Z)
|
||||
do_blocking_move_to_z(h_offset + new_z); // Move the nozzle as the point is edited
|
||||
#endif
|
||||
idle();
|
||||
} while (!ubl_lcd_clicked());
|
||||
|
@ -1581,7 +1575,8 @@
|
|||
}
|
||||
else lcd_return_to_status();
|
||||
}
|
||||
#endif
|
||||
|
||||
#endif // NEWPANEL
|
||||
|
||||
/**
|
||||
* 'Smart Fill': Scan from the outward edges of the mesh towards the center.
|
||||
|
|
Reference in a new issue