Dummy Thermistor Table for testing purposes
Am I the only one who always need to change the thermistortable.h to add a dummy table?? Ok, it is done. Just set the thermistor to 999 and it will always read 25C. Great for Testing or Development purposes.
This commit is contained in:
parent
c3c50528e6
commit
a57869ba49
2 changed files with 11 additions and 0 deletions
|
@ -118,6 +118,7 @@ Here are some standard links for getting your machine calibrated:
|
||||||
// 1010 is Pt1000 with 1k pullup (non standard)
|
// 1010 is Pt1000 with 1k pullup (non standard)
|
||||||
// 147 is Pt100 with 4k7 pullup
|
// 147 is Pt100 with 4k7 pullup
|
||||||
// 110 is Pt100 with 1k pullup (non standard)
|
// 110 is Pt100 with 1k pullup (non standard)
|
||||||
|
// 999 is a Dummy Table. It will ALWAYS read 25C.. Use it for Testing or Development purposes. NEVER for production machine.
|
||||||
|
|
||||||
#define TEMP_SENSOR_0 -1
|
#define TEMP_SENSOR_0 -1
|
||||||
#define TEMP_SENSOR_1 -1
|
#define TEMP_SENSOR_1 -1
|
||||||
|
|
|
@ -1095,6 +1095,16 @@ const short temptable_1047[][2] PROGMEM = {
|
||||||
};
|
};
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
#if (THERMISTORHEATER_0 == 999) || (THERMISTORHEATER_1 == 999) || (THERMISTORHEATER_2 == 999) || (THERMISTORHEATER_3 == 999) || (THERMISTORBED == 999) //User defined table
|
||||||
|
// Dummy Thermistor table.. It will ALWAYS read 25C.
|
||||||
|
const short temptable_999[][2] PROGMEM = {
|
||||||
|
{1*OVERSAMPLENR, 25},
|
||||||
|
{1023*OVERSAMPLENR, 25}
|
||||||
|
};
|
||||||
|
#endif
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
#define _TT_NAME(_N) temptable_ ## _N
|
#define _TT_NAME(_N) temptable_ ## _N
|
||||||
#define TT_NAME(_N) _TT_NAME(_N)
|
#define TT_NAME(_N) _TT_NAME(_N)
|
||||||
|
|
||||||
|
|
Reference in a new issue