Fix for M109 and M190 cooldown
Also removes the re-definition of now inside M190's while loop
This commit is contained in:
parent
47e3564bbd
commit
c218db136a
1 changed files with 21 additions and 17 deletions
|
@ -4242,12 +4242,11 @@ inline void gcode_M105() {
|
|||
* Rxxx Wait for extruder(s) to reach temperature. Waits when heating and cooling.
|
||||
*/
|
||||
inline void gcode_M109() {
|
||||
bool no_wait_for_cooling = true;
|
||||
|
||||
if (setTargetedHotend(109)) return;
|
||||
if (DEBUGGING(DRYRUN)) return;
|
||||
|
||||
no_wait_for_cooling = code_seen('S');
|
||||
bool no_wait_for_cooling = code_seen('S');
|
||||
if (no_wait_for_cooling || code_seen('R')) {
|
||||
float temp = code_value();
|
||||
setTargetHotend(temp, target_extruder);
|
||||
|
@ -4282,12 +4281,14 @@ inline void gcode_M109() {
|
|||
if (code_seen('B')) autotemp_max = code_value();
|
||||
#endif
|
||||
|
||||
// Exit if the temperature is above target and not waiting for cooling
|
||||
if (no_wait_for_cooling && !isHeatingHotend(target_extruder)) return;
|
||||
bool wants_to_cool = isCoolingHotend(target_extruder);
|
||||
|
||||
// Exit if S<lower>, continue if S<higher>, R<lower>, or R<higher>
|
||||
if (no_wait_for_cooling && wants_to_cool) return;
|
||||
|
||||
// Prevents a wait-forever situation if R is misused i.e. M109 R0
|
||||
// Try to calculate a ballpark safe margin by halving EXTRUDE_MINTEMP
|
||||
if (degTargetHotend(target_extruder) < (EXTRUDE_MINTEMP)/2) return;
|
||||
if (wants_to_cool && degTargetHotend(target_extruder) < (EXTRUDE_MINTEMP)/2) return;
|
||||
|
||||
#ifdef TEMP_RESIDENCY_TIME
|
||||
millis_t residency_start_ms = 0;
|
||||
|
@ -4295,12 +4296,12 @@ inline void gcode_M109() {
|
|||
#define TEMP_CONDITIONS (!residency_start_ms || PENDING(now, residency_start_ms + (TEMP_RESIDENCY_TIME) * 1000UL))
|
||||
#else
|
||||
// Loop until the temperature is very close target
|
||||
#define TEMP_CONDITIONS (isHeatingHotend(target_extruder))
|
||||
#define TEMP_CONDITIONS (wants_to_cool ? isCoolingHotend(target_extruder) : isHeatingHotend(target_extruder))
|
||||
#endif //TEMP_RESIDENCY_TIME
|
||||
|
||||
cancel_heatup = false;
|
||||
millis_t now = millis(), next_temp_ms = now + 1000UL;
|
||||
while (!cancel_heatup && TEMP_CONDITIONS) {
|
||||
millis_t now, next_temp_ms = 0;
|
||||
do {
|
||||
now = millis();
|
||||
if (ELAPSED(now, next_temp_ms)) { //Print temp & remaining time every 1s while waiting
|
||||
next_temp_ms = now + 1000UL;
|
||||
|
@ -4326,7 +4327,7 @@ inline void gcode_M109() {
|
|||
|
||||
#ifdef TEMP_RESIDENCY_TIME
|
||||
|
||||
float temp_diff = labs(degHotend(target_extruder) - degTargetHotend(target_extruder));
|
||||
float temp_diff = fabs(degTargetHotend(target_extruder) - degHotend(target_extruder));
|
||||
|
||||
if (!residency_start_ms) {
|
||||
// Start the TEMP_RESIDENCY_TIME timer when we reach target temp for the first time.
|
||||
|
@ -4339,7 +4340,7 @@ inline void gcode_M109() {
|
|||
|
||||
#endif //TEMP_RESIDENCY_TIME
|
||||
|
||||
} // while(!cancel_heatup && TEMP_CONDITIONS)
|
||||
} while (!cancel_heatup && TEMP_CONDITIONS);
|
||||
|
||||
LCD_MESSAGEPGM(MSG_HEATING_COMPLETE);
|
||||
}
|
||||
|
@ -4355,15 +4356,18 @@ inline void gcode_M109() {
|
|||
|
||||
LCD_MESSAGEPGM(MSG_BED_HEATING);
|
||||
bool no_wait_for_cooling = code_seen('S');
|
||||
if (no_wait_for_cooling || code_seen('R'))
|
||||
setTargetBed(code_value());
|
||||
if (no_wait_for_cooling || code_seen('R')) setTargetBed(code_value());
|
||||
|
||||
// Exit if the temperature is above target and not waiting for cooling
|
||||
if (no_wait_for_cooling && !isHeatingBed()) return;
|
||||
bool wants_to_cool = isCoolingBed();
|
||||
|
||||
// Exit if S<lower>, continue if S<higher>, R<lower>, or R<higher>
|
||||
if (no_wait_for_cooling && wants_to_cool) return;
|
||||
|
||||
cancel_heatup = false;
|
||||
millis_t now = millis(), next_temp_ms = now + 1000UL;
|
||||
while (!cancel_heatup && isHeatingBed()) {
|
||||
millis_t next_temp_ms = 0;
|
||||
|
||||
// Wait for temperature to come close enough
|
||||
do {
|
||||
millis_t now = millis();
|
||||
if (ELAPSED(now, next_temp_ms)) { //Print Temp Reading every 1 second while heating up.
|
||||
next_temp_ms = now + 1000UL;
|
||||
|
@ -4372,7 +4376,7 @@ inline void gcode_M109() {
|
|||
}
|
||||
idle();
|
||||
refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
|
||||
}
|
||||
} while (!cancel_heatup && (wants_to_cool ? isCoolingBed() : isHeatingBed()));
|
||||
LCD_MESSAGEPGM(MSG_BED_DONE);
|
||||
}
|
||||
|
||||
|
|
Reference in a new issue