From caeba33d28b420acb868599914abab3d2fd7cd49 Mon Sep 17 00:00:00 2001 From: Scott Lahteine Date: Tue, 16 Jun 2020 14:08:51 -0500 Subject: [PATCH] Sensor 502 and PTC cleanup --- Marlin/Configuration.h | 1 + Marlin/Configuration_adv.h | 20 ++++++++++---------- 2 files changed, 11 insertions(+), 10 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index 6352f9e6e..9109e723d 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -373,6 +373,7 @@ * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan, J-Head, and E3D) (4.7k pullup) * 501 : 100K Zonestar (Tronxy X3A) Thermistor + * 502 : 100K Zonestar Thermistor used by hot bed in Zonestar Prusa P802M * 512 : 100k RPW-Ultra hotend thermistor (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) diff --git a/Marlin/Configuration_adv.h b/Marlin/Configuration_adv.h index 7c9c8b066..b63253a27 100644 --- a/Marlin/Configuration_adv.h +++ b/Marlin/Configuration_adv.h @@ -1666,33 +1666,33 @@ // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. - // #define PTC_SAMPLE_START 30.0f - // #define PTC_SAMPLE_RES 5.0f - // #define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30.0f + //#define PTC_SAMPLE_RES 5.0f + //#define PTC_SAMPLE_COUNT 10U // Bed temperature calibration builds a similar table. - // #define BTC_SAMPLE_START 60.0f - // #define BTC_SAMPLE_RES 5.0f - // #define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60.0f + //#define BTC_SAMPLE_RES 5.0f + //#define BTC_SAMPLE_COUNT 10U // The temperature the probe should be at while taking measurements during bed temperature // calibration. - // #define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30.0f // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. - // #define PTC_PROBE_HEATING_OFFSET 0.5f + //#define PTC_PROBE_HEATING_OFFSET 0.5f // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - // #define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15U // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] // and data[4] to perform linear extrapolation for values below PTC_SAMPLE_START. - // #define PTC_LINEAR_EXTRAPOLATION 4 + //#define PTC_LINEAR_EXTRAPOLATION 4 #endif #endif