Use do_blocking_move_to where possible
This commit is contained in:
parent
36426af564
commit
d4a1154c25
3 changed files with 17 additions and 25 deletions
|
@ -260,13 +260,10 @@ void reset_bed_level() {
|
||||||
|
|
||||||
#if MANUAL_PROBE_HEIGHT > 0
|
#if MANUAL_PROBE_HEIGHT > 0
|
||||||
const float prev_z = current_position[Z_AXIS];
|
const float prev_z = current_position[Z_AXIS];
|
||||||
do_blocking_move_to_z(MANUAL_PROBE_HEIGHT, homing_feedrate(Z_AXIS));
|
do_blocking_move_to(rx, ry, MANUAL_PROBE_HEIGHT);
|
||||||
#endif
|
do_blocking_move_to_z(prev_z);
|
||||||
|
#else
|
||||||
do_blocking_move_to_xy(rx, ry, MMM_TO_MMS(XY_PROBE_SPEED));
|
do_blocking_move_to_xy(rx, ry);
|
||||||
|
|
||||||
#if MANUAL_PROBE_HEIGHT > 0
|
|
||||||
do_blocking_move_to_z(prev_z, homing_feedrate(Z_AXIS));
|
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
current_position[X_AXIS] = rx;
|
current_position[X_AXIS] = rx;
|
||||||
|
|
|
@ -467,6 +467,7 @@
|
||||||
//
|
//
|
||||||
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.");
|
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.");
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
||||||
|
|
||||||
if (!g29_x_flag && !g29_y_flag) {
|
if (!g29_x_flag && !g29_y_flag) {
|
||||||
/**
|
/**
|
||||||
* Use a good default location for the path.
|
* Use a good default location for the path.
|
||||||
|
@ -910,12 +911,11 @@
|
||||||
|
|
||||||
static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); }
|
static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); }
|
||||||
|
|
||||||
float unified_bed_leveling::measure_business_card_thickness(float in_height) {
|
float unified_bed_leveling::measure_business_card_thickness(const float in_height) {
|
||||||
has_control_of_lcd_panel = true;
|
has_control_of_lcd_panel = true;
|
||||||
save_ubl_active_state_and_disable(); // Disable bed level correction for probing
|
save_ubl_active_state_and_disable(); // Disable bed level correction for probing
|
||||||
|
|
||||||
do_blocking_move_to_z(in_height);
|
do_blocking_move_to(0.5 * (MESH_MAX_X - (MESH_MIN_X)), 0.5 * (MESH_MAX_Y - (MESH_MIN_Y)), in_height);
|
||||||
do_blocking_move_to_xy(0.5 * (MESH_MAX_X - (MESH_MIN_X)), 0.5 * (MESH_MAX_Y - (MESH_MIN_Y)));
|
|
||||||
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0);
|
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0);
|
||||||
stepper.synchronize();
|
stepper.synchronize();
|
||||||
|
|
||||||
|
@ -944,8 +944,6 @@
|
||||||
SERIAL_PROTOCOLLNPGM("mm thick.");
|
SERIAL_PROTOCOLLNPGM("mm thick.");
|
||||||
}
|
}
|
||||||
|
|
||||||
in_height = current_position[Z_AXIS]; // do manual probing at lower height
|
|
||||||
|
|
||||||
has_control_of_lcd_panel = false;
|
has_control_of_lcd_panel = false;
|
||||||
|
|
||||||
restore_ubl_active_state_and_leave();
|
restore_ubl_active_state_and_leave();
|
||||||
|
@ -958,8 +956,8 @@
|
||||||
has_control_of_lcd_panel = true;
|
has_control_of_lcd_panel = true;
|
||||||
|
|
||||||
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
||||||
do_blocking_move_to_xy(rx, ry);
|
do_blocking_move_to(rx, ry, Z_CLEARANCE_BETWEEN_PROBES);
|
||||||
|
|
||||||
lcd_return_to_status();
|
lcd_return_to_status();
|
||||||
|
|
||||||
|
@ -974,11 +972,9 @@
|
||||||
|
|
||||||
if (!position_is_reachable(xProbe, yProbe)) break; // SHOULD NOT OCCUR (find_closest_mesh_point only returns reachable points)
|
if (!position_is_reachable(xProbe, yProbe)) break; // SHOULD NOT OCCUR (find_closest_mesh_point only returns reachable points)
|
||||||
|
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
||||||
|
|
||||||
LCD_MESSAGEPGM(MSG_UBL_MOVING_TO_NEXT);
|
LCD_MESSAGEPGM(MSG_UBL_MOVING_TO_NEXT);
|
||||||
|
|
||||||
do_blocking_move_to_xy(xProbe, yProbe);
|
do_blocking_move_to(xProbe, yProbe, Z_CLEARANCE_BETWEEN_PROBES);
|
||||||
do_blocking_move_to_z(z_clearance);
|
do_blocking_move_to_z(z_clearance);
|
||||||
|
|
||||||
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
||||||
|
@ -1035,8 +1031,7 @@
|
||||||
|
|
||||||
restore_ubl_active_state_and_leave();
|
restore_ubl_active_state_and_leave();
|
||||||
KEEPALIVE_STATE(IN_HANDLER);
|
KEEPALIVE_STATE(IN_HANDLER);
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
do_blocking_move_to(rx, ry, Z_CLEARANCE_DEPLOY_PROBE);
|
||||||
do_blocking_move_to_xy(rx, ry);
|
|
||||||
}
|
}
|
||||||
|
|
||||||
#endif // NEWPANEL
|
#endif // NEWPANEL
|
||||||
|
@ -1486,8 +1481,7 @@
|
||||||
|
|
||||||
LCD_MESSAGEPGM(MSG_UBL_FINE_TUNE_MESH);
|
LCD_MESSAGEPGM(MSG_UBL_FINE_TUNE_MESH);
|
||||||
|
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
do_blocking_move_to(rx, ry, Z_CLEARANCE_BETWEEN_PROBES);
|
||||||
do_blocking_move_to_xy(rx, ry);
|
|
||||||
|
|
||||||
uint16_t not_done[16];
|
uint16_t not_done[16];
|
||||||
memset(not_done, 0xFF, sizeof(not_done));
|
memset(not_done, 0xFF, sizeof(not_done));
|
||||||
|
@ -1510,8 +1504,7 @@
|
||||||
if (isnan(new_z)) // if the mesh point is invalid, set it to 0.0 so it can be edited
|
if (isnan(new_z)) // if the mesh point is invalid, set it to 0.0 so it can be edited
|
||||||
new_z = 0.0;
|
new_z = 0.0;
|
||||||
|
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); // Move the nozzle to where we are going to edit
|
do_blocking_move_to(rawx, rawy, Z_CLEARANCE_BETWEEN_PROBES); // Move the nozzle to the edit point
|
||||||
do_blocking_move_to_xy(rawx, rawy);
|
|
||||||
|
|
||||||
new_z = FLOOR(new_z * 1000.0) * 0.001; // Chop off digits after the 1000ths place
|
new_z = FLOOR(new_z * 1000.0) * 0.001; // Chop off digits after the 1000ths place
|
||||||
|
|
||||||
|
@ -1571,9 +1564,8 @@
|
||||||
|
|
||||||
if (do_ubl_mesh_map) display_map(g29_map_type);
|
if (do_ubl_mesh_map) display_map(g29_map_type);
|
||||||
restore_ubl_active_state_and_leave();
|
restore_ubl_active_state_and_leave();
|
||||||
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
||||||
|
|
||||||
do_blocking_move_to_xy(rx, ry);
|
do_blocking_move_to(rx, ry, Z_CLEARANCE_BETWEEN_PROBES);
|
||||||
|
|
||||||
LCD_MESSAGEPGM(MSG_UBL_DONE_EDITING_MESH);
|
LCD_MESSAGEPGM(MSG_UBL_DONE_EDITING_MESH);
|
||||||
SERIAL_ECHOLNPGM("Done Editing Mesh");
|
SERIAL_ECHOLNPGM("Done Editing Mesh");
|
||||||
|
|
|
@ -785,6 +785,9 @@ float soft_endstop_min[XYZ] = { X_MIN_BED, Y_MIN_BED, Z_MIN_POS },
|
||||||
*
|
*
|
||||||
* This may result in several calls to planner.buffer_line to
|
* This may result in several calls to planner.buffer_line to
|
||||||
* do smaller moves for DELTA, SCARA, mesh moves, etc.
|
* do smaller moves for DELTA, SCARA, mesh moves, etc.
|
||||||
|
*
|
||||||
|
* Make sure current_position[E] and destination[E] are good
|
||||||
|
* before calling or cold/lengthy extrusion may get missed.
|
||||||
*/
|
*/
|
||||||
void prepare_move_to_destination() {
|
void prepare_move_to_destination() {
|
||||||
clamp_to_software_endstops(destination);
|
clamp_to_software_endstops(destination);
|
||||||
|
|
Reference in a new issue