Cleanups for PTC
This commit is contained in:
parent
be62ab2d02
commit
e5d39063a2
2 changed files with 15 additions and 15 deletions
|
@ -57,16 +57,16 @@ class ProbeTempComp {
|
|||
static const temp_calib_t cali_info[TSI_COUNT];
|
||||
|
||||
// Where to park nozzle to wait for probe cooldown
|
||||
static constexpr xyz_pos_t park_point = xyz_pos_t({ PTC_PARK_POS_X, PTC_PARK_POS_Y, PTC_PARK_POS_Z });
|
||||
static constexpr float park_point_x = PTC_PARK_POS_X,
|
||||
park_point_y = PTC_PARK_POS_Y,
|
||||
park_point_z = PTC_PARK_POS_Z,
|
||||
// XY coordinates of nozzle for probing the bed
|
||||
measure_point_x = PTC_PROBE_POS_X, // Coordinates to probe
|
||||
measure_point_y = PTC_PROBE_POS_Y;
|
||||
//measure_point_x = 12.0f, // Coordinates to probe on MK52 magnetic heatbed
|
||||
//measure_point_y = 7.3f;
|
||||
|
||||
static constexpr int max_bed_temp = PTC_MAX_BED_TEMP, // Max temperature to avoid heating errors
|
||||
|
||||
// XY coordinates of nozzle for probing the bed
|
||||
measure_point_x = PTC_PROBE_POS_X, // X-coordinate to probe
|
||||
measure_point_y = PTC_PROBE_POS_Y, // Y-coordinate to probe
|
||||
//measure_point_x = 12.0f, // X-coordinate to probe on MK52 magnetic heatbed
|
||||
//measure_point_y = 7.3f, // Y-coordinate to probe on MK52 magnetic heatbed
|
||||
|
||||
probe_calib_bed_temp = max_bed_temp, // Bed temperature while calibrating probe
|
||||
bed_calib_probe_temp = 30; // Probe temperature while calibrating bed
|
||||
|
||||
|
|
|
@ -105,8 +105,8 @@ void GcodeSuite::G76() {
|
|||
|
||||
if (do_bed_cal || do_probe_cal) {
|
||||
// Ensure park position is reachable
|
||||
if (!position_is_reachable(ProbeTempComp::park_point.x, ProbeTempComp::park_point.y)
|
||||
|| !(WITHIN(ProbeTempComp::park_point.z, Z_MIN_POS - 0.001f, Z_MAX_POS + 0.001f))
|
||||
if (!position_is_reachable(temp_comp.park_point_x, temp_comp.park_point_y)
|
||||
|| !(WITHIN(temp_comp.park_point_z, Z_MIN_POS - 0.001f, Z_MAX_POS + 0.001f))
|
||||
) {
|
||||
SERIAL_ECHOLNPGM("!Park position unreachable - aborting.");
|
||||
return;
|
||||
|
@ -161,7 +161,7 @@ void GcodeSuite::G76() {
|
|||
SERIAL_ECHOLNPAIR("Target Bed: ", target_bed, "; Probe: ", target_probe);
|
||||
|
||||
// Park nozzle
|
||||
do_blocking_move_to(ProbeTempComp::park_point.x, ProbeTempComp::park_point.y, ProbeTempComp::park_point.z);
|
||||
do_blocking_move_to(temp_comp.park_point_x, temp_comp.park_point_y, temp_comp.park_point_z);
|
||||
|
||||
// Wait for heatbed to reach target temp and probe to cool below target temp
|
||||
SERIAL_ECHOLNPGM("Waiting for bed and probe to reach target temp.");
|
||||
|
@ -186,9 +186,9 @@ void GcodeSuite::G76() {
|
|||
|
||||
if (timeout) break;
|
||||
|
||||
// Move probe to probing point and wait for probe to reach target temp
|
||||
// Move the nozzle to the probing point and wait for the probe to reach target temp
|
||||
destination.set(temp_comp.measure_point_x, temp_comp.measure_point_y, 0.5);
|
||||
do_blocking_move_to(destination.x, destination.y, destination.z);
|
||||
do_blocking_move_to(destination);
|
||||
SERIAL_ECHOLNPGM("Waiting for probe heating.");
|
||||
while (thermalManager.degProbe() < target_probe) {
|
||||
idle(
|
||||
|
@ -207,7 +207,7 @@ void GcodeSuite::G76() {
|
|||
destination.z = 5.0;
|
||||
do_blocking_move_to_z(destination.z);
|
||||
|
||||
// Do a single probe
|
||||
// Do a single probe at the current position
|
||||
remember_feedrate_scaling_off();
|
||||
const float measured_z = probe.probe_at_point(
|
||||
destination.x + probe.offset_xy.x,
|
||||
|
@ -252,7 +252,7 @@ void GcodeSuite::G76() {
|
|||
if (do_probe_cal) {
|
||||
|
||||
// Park nozzle
|
||||
do_blocking_move_to(ProbeTempComp::park_point.x, ProbeTempComp::park_point.y, ProbeTempComp::park_point.z);
|
||||
do_blocking_move_to(temp_comp.park_point_x, temp_comp.park_point_y, temp_comp.park_point_z);
|
||||
|
||||
// Initialize temperatures
|
||||
uint16_t target_bed = temp_comp.probe_calib_bed_temp,
|
||||
|
|
Reference in a new issue