Commit graph

200 commits

Author SHA1 Message Date
Scott Lahteine 2deff0d9b9 Fix/Improve junction deviation
- Respect axis max acceleration limits instead of forcing a fixed acceleration value.
- The `junction_unit_vec` ensures proper handling of entry and exit speeds even when the axes involved have different limits.
2018-05-31 20:09:53 -05:00
Scott Lahteine 9713538427 HOTENDS for Switching Nozzle with Switching Extruder 2018-05-29 11:05:52 -05:00
Scott Lahteine 0ca9db7051 Correct HOTENDS for SWITCHING_EXTRUDER 2018-05-27 23:22:48 -05:00
Scott Lahteine 1b200f3312 Sanity check SWITCHING_EXTRUDER with SINGLENOZZLE 2018-05-26 23:26:23 -05:00
Scott Lahteine 931ab4ec40 Rename Junction Deviation options 2018-05-26 18:33:51 -05:00
Scott Lahteine aaaf09bda2 BEZIER_JERK_CONTROL => S_CURVE_ACCELERATION 2018-05-26 18:33:51 -05:00
Scott Lahteine cf7d5a642a
Fix manual moves for switching tools (#10868) 2018-05-26 18:30:53 -05:00
Scott Lahteine 4118199ddd Tweaks to core headers 2018-05-21 20:32:18 -05:00
Bob Kuhn d557c84a71 [2.0.x] Error for FAST_PWM_FAN with 32 bit CPU (#10798) 2018-05-20 11:37:55 -05:00
Scott Lahteine 83d42f33e1 Add HAS_HOTEND_OFFSET_Z conditional 2018-05-19 17:05:15 -05:00
GMagician 3c76bda2d8 Fix switching extruder
`DONT_SWITCH` got lost along the way. Replace it with `DO_SWITCH_EXTRUDER` and adjust the code.
2018-05-19 17:05:15 -05:00
Jiri Jaburek 43ddb29f9e Add FAN_MAX_PWM for M106-controlled fans 2018-05-15 21:18:46 -05:00
Scott Lahteine b7dfc79988
Disable SERIAL_PORT_2 by default and sanity-check it (#10748) 2018-05-14 21:38:24 -05:00
Scott Lahteine 99ecdf59af Smarter MIN, MAX, ABS macros
Use macros that explicitly avoid double-evaluation and can be used for any datatype, replacing `min`, `max`, `abs`, `fabs`, `labs`, and `FABS`.

Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-13 04:52:56 -05:00
Scott Lahteine a1062eec5b
Better handling of DELAY_NS and DELAY_US (#10716)
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-12 08:34:04 -05:00
Scott Lahteine 325bbbc8c2
[2.0.x] Enable AD595 and AD8495 in concert (#10693)
* Allow both AD595 and AD8495 in concert
* General temperature code tweaks
2018-05-11 01:01:51 -05:00
Scott Lahteine 19f189b4e5
Add UBL support for G2/G3 and G5 (#10648) 2018-05-08 11:10:45 -05:00
Giuliano 4e16e699c1 Fix sanity checks for dual axes (#10633) 2018-05-07 03:34:26 -05:00
Scott Lahteine e978e6e782
[2.0.x] Arrange LCD options by type (#10630) 2018-05-06 19:16:55 -05:00
Scott Lahteine 8c5bc77fb9 Fix the sanity-check for config versions 2018-05-06 09:37:00 -05:00
Scott Lahteine 81b632c255 Additional temp-oriented improvements 2018-05-02 08:43:22 -05:00
nightdemonx e911635fb1 Add thermocouple with AD8495 support 2018-05-02 08:43:16 -05:00
Scott Lahteine b7e938a9fb LCD_BED_LEVELING enables a sub-menu for ABL 2018-05-01 07:13:56 -05:00
Scott Lahteine 05c33833e7
[2.0.x] Add NO_LCD_MENUS option (#10582) 2018-04-30 21:16:31 -05:00
Scott Lahteine 616651ff23 Add sanity check for LED_CONTROL_MENU
Addressing #10569
2018-04-29 18:34:57 -05:00
Scott Lahteine f790b4bc0a Reorganize some conditionals 2018-04-27 02:23:11 -05:00
Scott Lahteine df6bc812b5 Fix disable of Z_HOMING_SENSITIVITY for HOMING_Z_WITH_PROBE
As pointed out in #10532
2018-04-27 02:23:10 -05:00
Scott Lahteine 299c4fed42 Undefine PIDTEMPBED without a bed heater 2018-04-26 01:30:10 -05:00
Scott Lahteine cb46cb8480
Add HAS_HEATED_BED conditional (#10495) 2018-04-23 17:13:01 -05:00
Scott Lahteine 9e07df5c1b
Extra options for LEVEL_BED_CORNERS (#10483) 2018-04-22 02:50:48 -05:00
Scott Lahteine 11ab017dd0 Creality3D Power-Loss Recovery 2018-04-21 21:56:50 -05:00
Scott Lahteine a0dac95d25
Merge pull request #10460 from thinkyhead/bf2_trigorilla_14
[2.0.x] Split TRIGORILLA into 1.3 and 1.4
2018-04-20 18:25:40 -05:00
Scott Lahteine f0cbf3d432 Correction to sanity check 2018-04-20 18:16:27 -05:00
Scott Lahteine 80e29492c6 TRIGORILLA => TRIGORILLA_13 2018-04-20 16:12:25 -05:00
Marcio Teixeira 5cc7916e69 Add G29_RETRY_AND_RECOVER feature
- Add an option to retry G29, optionally executing a G-code procedure after each failed probe.
2018-04-19 19:45:53 -05:00
Scott Lahteine 4f184ba5da
[2.0.x] Add BOARD_MKS_BASE_15 with digital micro-stepping (#10454)
* Add BOARD_MKS_BASE_15 with digital micro-stepping
* Rename MKS_13 to MKS_GEN_13
2018-04-18 22:58:43 -05:00
Scott Lahteine 39c6f65ce7 Ignore LCD_BED_LEVELING with UBL 2018-04-17 15:57:44 -05:00
Chris Pepper c9aed73987 Fix missed includes from HAL macro patch (#10416) 2018-04-15 18:27:34 -05:00
Chris Pepper cc6d41e1d3 Use a macro for HAL header redirection (#10380) 2018-04-12 20:25:08 -05:00
Luc Van Daele 12785583d0 [2.0.x] G33 MIN_STEPS_PER_SEGMENT (#10386) 2018-04-12 20:22:29 -05:00
Yunhui Fu c96412a78f [2.0.x] UTF-8 language translation support (#10213) 2018-04-12 20:14:01 -05:00
Eduardo José Tagle 57a899a412 [2.0.x] 6th-order jerk-controlled motion planning in real-time for AVR (#10373) 2018-04-11 18:13:42 -05:00
Sean 2d9b0a66fe Add Filament Change accelerations 2018-04-09 23:57:27 -05:00
Scott Lahteine 8b8ad14178 Add Z_PROBE_LOW_POINT to prevent damage 2018-04-09 17:23:03 -05:00
Scott Lahteine e02fc4f1d6 Better RESTORE_LEVELING_AFTER_G28 sanity-check
As suggested by @GMagician
2018-04-08 03:24:15 -05:00
etagle a29adde5c0 Implement BEZIER_JERK_CONTROL
Enable 6th-order jerk-controlled motion planning in real-time.
Only for 32bit MCUs. (AVR simply does not have enough processing power for this!)
2018-04-07 21:03:28 -05:00
Lenbok 0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
Marcio Teixeira 75037493fa Default active low for TMC2130 DIAG1 (#10294)
- Added sanity check to inform users to set the endstop to inverting
  when using SENSORLESS_HOMING
2018-04-06 19:48:46 -05:00
Karl Andersson 7cbbc2af7a [2.0.x] Optional heater signal inversion (#10260) 2018-04-02 19:37:41 -05:00
Scott Lahteine adcb87f0db Z Endstop Servo => Z Probe Servo 2018-04-01 23:54:21 -05:00