Commit graph

25 commits

Author SHA1 Message Date
fixoid
c2321b1cdd Separate SWITCHING_NOZZLE and SWITCHING_EXTRUDER 2017-05-16 19:25:17 -05:00
Brian
2604742191 Add proportional font adjustment ratio
- update example configs
2017-05-10 17:19:03 -04:00
Scott Lahteine
1c4ed8b106 Note 5 extruders in config comments 2017-05-07 21:28:54 -05:00
Brian
faa270071d Improve BLTOUCH_HEATERS_OFF functionality
- rename to PROBING_HEATERS_OFF
 - move heater pausing functionality into thermalManager
   - add variables, pause(), ispaused(), other functions
 - add fan pausing functionality -> PROBING_FANS_OFF
 - add probing_pause() wrapper
 - move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
 - example configs
2017-05-07 16:22:08 -04:00
Scott Lahteine
77769e284f Edit configuration comments 2017-05-05 13:32:31 -05:00
Scott Lahteine
628391304f Merge pull request #6552 from thinkyhead/rc_more_ubl_cleanup
Further cleanup of UBL
2017-05-02 22:46:04 -05:00
Scott Lahteine
2c13922c46 Implement USE_CONTROLLER_FAN as a feature 2017-05-02 20:18:52 -05:00
Scott Lahteine
b93be716cf Remove trailing whitespace 2017-05-02 17:53:40 -05:00
Scott Lahteine
671a44b8aa Merge pull request #6410 from teemuatlut/LVD-Delta
Delta auto-calibration updates
2017-04-30 16:39:51 -05:00
Scott Lahteine
54751e8557 Put DISTINCT_E_FACTORS adjacent to the affected settings 2017-04-30 15:30:31 -05:00
Scott Lahteine
0dbe4b3e54 Edit configurations to reduce verbosity, arrange logically 2017-04-30 15:30:31 -05:00
Scott Lahteine
d7d4378481 Remove inaccurate version description 2017-04-30 14:57:19 -05:00
LVD-AC
585c00a728 Proposed changes
This is what I did yesterday:

- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)

- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets

- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)

-Wrote 3 dummies to keep EEPROM lenght the same

-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
2017-04-29 18:53:14 +03:00
Scott Lahteine
baf3b91460 DELTA_TOWER_ANGLE_TRIM only needs AB 2017-04-29 15:29:49 +03:00
LVD-AC
ed6b361e27 cleanup ready to squash 2017-04-28 18:09:18 +03:00
Roxy-3D
4075b95519 Allow BL-Touch users to control heaters during probe event (#6485)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375      // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
2017-04-28 09:19:55 -05:00
LVD-AC
dcf30a69d6 Allowing #define DELTA_TOWER_ANGLE_TRIM[C_AXIS]
More consistent with M665 where C-value is allowed as well, then
normalized
2017-04-23 14:51:24 +03:00
Scott Lahteine
959566cf0a Update note about M163 / M164 2017-04-22 16:23:15 -05:00
LVD-AC
d4f593d200 Delete 'expert level'
and getting rid off verbose level 3 and configuration_adv settings
2017-04-21 11:58:39 +03:00
LVD-AC
13c8493878 M665 rework and related issues (all delta's)
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration)

- M665 B also sets the radius for manual calibration menu

- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard

- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define
2017-04-21 11:58:39 +03:00
Scott Lahteine
b0aa256bc0 Updates for all configs 2017-04-20 17:52:05 -05:00
Scott Lahteine
a00ae4790a Replace M905 with unique code M900 2017-04-17 16:39:37 -05:00
Scott Lahteine
d60c02c5b1 Cleanup, extend TMC2130 configuration 2017-04-14 22:43:56 -05:00
Scott Lahteine
0e97b3d6d0 Fix some configuration spacing 2017-04-14 22:36:10 -05:00
LVD-AC
03bda24d19 Add delta auto-calibration and configuration for Flsun AC 2017-04-14 19:08:14 -05:00