Scott Lahteine
1c384930f3
Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
...
Wrap macros to prevent bad expansions
2016-03-15 00:25:34 -07:00
esenapaj
a4314c4907
Use local variable in recalc_delta_settings()
...
diagonal_rod hadn't been used anywhere.
2016-03-15 06:47:27 +09:00
Scott Lahteine
3f5fbbd398
Merge pull request #3124 from jbrazio/bugfix/update-g29-auto-level-bed-topography
...
Update the bed topography output done by G29
2016-03-13 03:51:43 -07:00
Scott Lahteine
f9ded2a7c4
Wrap macros to prevent bad expansions
2016-03-12 22:38:55 -08:00
jbrazio
1981e53d68
M109 R option if misused could cause a wait-forever situation
2016-03-12 06:24:24 +00:00
João Brázio
4d4a842cfb
Update the bed topography output done by G29
2016-03-10 13:24:17 +00:00
AnHardt
fd5414c6ea
Z_RAISE_BEFORE_HOMING -> MIN_Z_HEIGHT_FOR_HOMING
...
rebased
corrected spelling
changed to #elif for error
Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
2016-03-08 17:50:23 +01:00
Scott Lahteine
b7928a000a
Merge pull request #3108 from AnHardt/M110+
...
M110 and M29 rework
2016-03-08 03:54:07 -08:00
Scott Lahteine
5cba0b4187
Merge pull request #3111 from thinkyhead/rc_drop_old_condition
...
Drop obsolete test for leading "N"
2016-03-08 03:07:25 -08:00
Scott Lahteine
302d1bfbc4
Drop obsolete test for leading "N"
2016-03-08 02:25:11 -08:00
AnHardt
37b857e8ec
M110 ang M29 rework
...
Add 'ok' output for G29 actually closing the file.
Handle M110 when received without linenumber/checksumm.
2016-03-07 22:27:01 +01:00
Scott Lahteine
fac85f6fa1
Merge pull request #3102 from jbrazio/bugfix-g28-multiple-z-movements
...
Bugfix: G28 was lifting Z-axis multiple times
2016-03-07 03:52:00 -08:00
jbrazio
642e3699ce
Z-axis was being lift multiple times if Z_SAFE_HOMING was enabled and Z_RAISE_BEFORE_HOMING was greater than zero
2016-03-07 03:49:11 +00:00
Scott Lahteine
501f63802a
Merge pull request #3077 from Blue-Marlin/watchdogreset-in-kill
...
Add Watchdog timer reset in kill()
2016-03-06 16:21:39 -08:00
Scott Lahteine
ef68c1910c
Check that the temperature is close to target
2016-03-06 05:51:56 -08:00
Scott Lahteine
ea9fd1200b
Fix M109 so it won't wait for cooling
...
Addressing issue #2767
2016-03-06 05:51:56 -08:00
Scott Lahteine
ff13070b59
Use _BV macros, patch up others
2016-03-06 05:51:55 -08:00
Scott Lahteine
209f5f21e0
Use macros where possible
...
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
2016-03-06 05:51:55 -08:00
Scott Lahteine
6e64895c30
Merge pull request #3001 from AlwaysTinkering/RCBugFix
...
Rc bug fix - Fix for issue #2931
2016-03-06 00:20:29 -08:00
Scott Lahteine
34b8b9f0f5
Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
...
Add CORE support to st_get_position_mm (and elsewhere)
2016-03-06 00:17:03 -08:00
Scott Lahteine
3a3d358df9
Fix Printrboard with LCD (redo)
...
Based on #2860 - rebased for RCBugFix
2016-03-05 22:13:00 -08:00
Scott Lahteine
eb85342fd9
Merge pull request #2989 from AnHardt/fix2661
...
Pre home display - Stepper release
2016-03-05 21:30:17 -08:00
Scott Lahteine
14f3ca1b2e
Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
...
Apply bed leveling matrix when switching extruders
2016-03-05 21:23:25 -08:00
lrpirlet
0fb507a75d
correct raise_z_for_servo
2016-03-05 20:19:53 -08:00
Blue-Marlin
b4e5e0f11d
Add Watchdog reset in kill()
...
Add watchdog reset in the kill loop to simplify recovering.
2016-03-04 00:35:18 +01:00
Scott Lahteine
222d13d5ed
Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
...
Code cleanup in gcode_T
2016-03-02 03:45:40 -08:00
Scott Lahteine
186629aee8
Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
...
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
2016-03-02 03:14:27 -08:00
jbrazio
67e15aac3d
As pointed out by @Blue-Marlin the previous code would raise the Z axis
...
twice for a servo based probe.
2016-03-01 00:22:48 +00:00
jbrazio
17cc2a9663
Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
...
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
2016-02-29 15:48:26 +00:00
AnHardt
1c889cd303
Refresh previous_cmd_ms during run_z_probe()
...
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238 )
2016-02-28 23:20:12 +01:00
AnHardt
4b02f33e69
Distribute config-changes to the other configurations
2016-02-28 23:20:04 +01:00
AnHardt
32ae9f9ab7
Fix stepper shutdown during waiting for temperatures
...
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.
The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.
# Conflicts:
# Marlin/Configuration_adv.h
2016-02-28 16:58:50 +01:00
AnHardt
b6e69e71ce
Make stepper shutdown after inactivity dependent
...
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E
And make exemplaric Configuration.
Names can be discussed.
This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
2016-02-28 16:58:42 +01:00
AnHardt
051325ccd7
Introduce axis_homed
...
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".
# Conflicts:
# Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:28 +01:00
Scott Lahteine
100271e6ac
minor cleanup in gcode_T
2016-02-27 19:56:56 -08:00
Scott Lahteine
6a4f06d35d
Fix GCode handling of spaces between command letter and first digit
2016-02-26 18:42:59 -08:00
CONSULitAS
ea8409ad5d
Fix: current_command_args contains command
...
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.
see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on
Greetings and welcome back
Jochen
2016-02-24 09:35:04 +01:00
Scott Lahteine
e1beaf61eb
Merge pull request #2985 from AnHardt/adv-ok
...
Repair N in ADVANCED_OK
2016-02-18 17:06:26 -08:00
Scott Lahteine
0c9db67273
Merge pull request #2983 from AnHardt/ok-echo
...
Replace the "ok" in M280, M301, M304, M851 with output not including …
2016-02-17 19:09:41 -08:00
Scott Lahteine
8eaba020fb
Merge pull request #2973 from thinkyhead/fix_splash_url
...
Remove references to marlinfirmware.org
2016-02-17 17:05:06 -08:00
Scott Lahteine
be691b51f1
Remove references to marlinfirmware.org
...
The domain is gone and doesn’t redirect, so for now show no URL on the boot screen.
2016-02-17 14:41:46 -08:00
Scott Lahteine
83ffc9eb4f
Show raw steps in M114
...
This is a proposed change. This section of M114 output is a debug
extension according to RepRap wiki.
2016-02-15 15:59:24 -08:00
Scott Lahteine
373e8a1ad4
Fixes for COREXY and COREXZ coordinates
2016-02-15 15:59:24 -08:00
unknown
31656e68bc
Fix for homing X and Y before raising Z when Z_SAFE_HOMING is set.
2016-02-15 15:53:40 -06:00
unknown
8ea55323d8
Fix for not raising Z before homing X and Y
2016-02-15 14:52:04 -06:00
Scott Lahteine
711e5db19a
Tweak comment in process_next_command
2016-02-09 18:16:35 -08:00
Scott Lahteine
400e9329be
Allow spaces after a code letter
2016-02-09 18:03:13 -08:00
Scott Lahteine
cdcb80f3c5
Allow no-space after initial command
...
Addresses issue #2715
2016-02-09 18:00:35 -08:00
AnHardt
6f473f7fc6
Repair N in ADVANCED_OK
...
Send the correct line number.
If no N was in the command - non't send an N.
2016-02-09 19:23:26 +01:00
AnHardt
efbd705eda
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
...
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
to avoid senting two "ok"s for a single g-code.
Doing the same for M105 would break the input filters of the hosts.
For M105 the other "ok" is omitted.
2016-02-09 13:36:03 +01:00