This repository has been archived on 2022-01-28. You can view files and clone it, but cannot push or open issues or pull requests.
Marlin-Artillery-M600/Marlin/SanityCheck.h
2015-05-21 11:47:34 -05:00

328 lines
11 KiB
C

/**
* SanityCheck.h
*
* Test configuration values for errors at compile-time.
*/
#ifndef SANITYCHECK_H
#define SANITYCHECK_H
/**
* Dual Stepper Drivers
*/
#if defined(Z_DUAL_STEPPER_DRIVERS) && defined(Y_DUAL_STEPPER_DRIVERS)
#error You cannot have dual stepper drivers for both Y and Z.
#endif
/**
* Progress Bar
*/
#ifdef LCD_PROGRESS_BAR
#ifndef SDSUPPORT
#error LCD_PROGRESS_BAR requires SDSUPPORT.
#endif
#ifdef DOGLCD
#error LCD_PROGRESS_BAR does not apply to graphical displays.
#endif
#ifdef FILAMENT_LCD_DISPLAY
#error LCD_PROGRESS_BAR and FILAMENT_LCD_DISPLAY are not fully compatible. Comment out this line to use both.
#endif
#endif
/**
* Babystepping
*/
#ifdef BABYSTEPPING
#ifdef COREXY
#error BABYSTEPPING not implemented for COREXY yet.
#endif
#ifdef SCARA
#error BABYSTEPPING is not implemented for SCARA yet.
#endif
#if defined(DELTA) && defined(BABYSTEP_XY)
#error BABYSTEPPING only implemented for Z axis on deltabots.
#endif
#endif
/**
* Filament Change with Extruder Runout Prevention
*/
#if defined(FILAMENTCHANGEENABLE) && defined(EXTRUDER_RUNOUT_PREVENT)
#error EXTRUDER_RUNOUT_PREVENT currently incompatible with FILAMENTCHANGE.
#endif
/**
* Options only for EXTRUDERS == 1
*/
#if EXTRUDERS > 1
#if EXTRUDERS > 4
#error The maximum number of EXTRUDERS in Marlin is 4.
#endif
#ifdef TEMP_SENSOR_1_AS_REDUNDANT
#error EXTRUDERS must be 1 with TEMP_SENSOR_1_AS_REDUNDANT.
#endif
#ifdef HEATERS_PARALLEL
#error EXTRUDERS must be 1 with HEATERS_PARALLEL.
#endif
#ifdef Y_DUAL_STEPPER_DRIVERS
#error EXTRUDERS must be 1 with Y_DUAL_STEPPER_DRIVERS.
#endif
#ifdef Z_DUAL_STEPPER_DRIVERS
#error EXTRUDERS must be 1 with Z_DUAL_STEPPER_DRIVERS.
#endif
#endif // EXTRUDERS > 1
/**
* Limited number of servos
*/
#if NUM_SERVOS > 4
#error The maximum number of SERVOS in Marlin is 4.
#endif
/**
* Required LCD language
*/
#if !defined(DOGLCD) && defined(ULTRA_LCD) && !defined(DISPLAY_CHARSET_HD44780_JAPAN) && !defined(DISPLAY_CHARSET_HD44780_WESTERN)&& !defined(DISPLAY_CHARSET_HD44780_CYRILLIC)
#error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
#endif
/**
* Mesh Bed Leveling
*/
#ifdef MESH_BED_LEVELING
#ifdef DELTA
#error MESH_BED_LEVELING does not yet support DELTA printers
#endif
#ifdef ENABLE_AUTO_BED_LEVELING
#error Select ENABLE_AUTO_BED_LEVELING or MESH_BED_LEVELING, not both
#endif
#if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
#error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8
#endif
#endif
/**
* Auto Bed Leveling
*/
#ifdef ENABLE_AUTO_BED_LEVELING
/**
* Require a Z Min pin
*/
#if Z_MIN_PIN == -1
#if Z_PROBE_PIN == -1 || (!defined(Z_PROBE_ENDSTOP) || defined(DISABLE_Z_PROBE_ENDSTOP)) // It's possible for someone to set a pin for the Z Probe, but not enable it.
#ifdef Z_PROBE_REPEATABILITY_TEST
#error You must have a Z_MIN or Z_PROBE endstop to enable Z_PROBE_REPEATABILITY_TEST.
#else
#error ENABLE_AUTO_BED_LEVELING requires a Z_MIN or Z_PROBE endstop. Z_MIN_PIN or Z_PROBE_PIN must point to a valid hardware pin.
#endif
#endif
#endif
/**
* Require a Z Probe Pin if Z_PROBE_ENDSTOP is enabled.
*/
#if defined(Z_PROBE_ENDSTOP)
#ifndef Z_PROBE_PIN
#error You must have a Z_PROBE_PIN defined in your pins_XXXX.h file if you enable Z_PROBE_ENDSTOP
#endif
#if Z_PROBE_PIN == -1
#error You must set Z_PROBE_PIN to a valid pin if you enable Z_PROBE_ENDSTOP
#endif
// Forcing Servo definitions can break some hall effect sensor setups. Leaving these here for further comment.
// #ifndef NUM_SERVOS
// #error You must have NUM_SERVOS defined and there must be at least 1 configured to use Z_PROBE_ENDSTOP
// #endif
// #if defined(NUM_SERVOS) && NUM_SERVOS < 1
// #error You must have at least 1 servo defined for NUM_SERVOS to use Z_PROBE_ENDSTOP
// #endif
// #ifndef SERVO_ENDSTOPS
// #error You must have SERVO_ENDSTOPS defined and have the Z index set to at least 0 or above to use Z_PROBE_ENDSTOP
// #endif
// #ifndef SERVO_ENDSTOP_ANGLES
// #error You must have SERVO_ENDSTOP_ANGLES defined for Z Extend and Retract to use Z_PROBE_AND_ENSTOP
// #endif
#endif
/**
* Check if Probe_Offset * Grid Points is greater than Probing Range
*/
#ifdef AUTO_BED_LEVELING_GRID
#ifndef DELTA_PROBABLE_RADIUS
// Make sure probing points are reachable
#if LEFT_PROBE_BED_POSITION < MIN_PROBE_X
#error "The given LEFT_PROBE_BED_POSITION can't be reached by the probe."
#elif RIGHT_PROBE_BED_POSITION > MAX_PROBE_X
#error "The given RIGHT_PROBE_BED_POSITION can't be reached by the probe."
#elif FRONT_PROBE_BED_POSITION < MIN_PROBE_Y
#error "The given FRONT_PROBE_BED_POSITION can't be reached by the probe."
#elif BACK_PROBE_BED_POSITION > MAX_PROBE_Y
#error "The given BACK_PROBE_BED_POSITION can't be reached by the probe."
#endif
#endif
#define PROBE_SIZE_X (X_PROBE_OFFSET_FROM_EXTRUDER * (AUTO_BED_LEVELING_GRID_POINTS-1))
#define PROBE_SIZE_Y (Y_PROBE_OFFSET_FROM_EXTRUDER * (AUTO_BED_LEVELING_GRID_POINTS-1))
#define PROBE_AREA_WIDTH (RIGHT_PROBE_BED_POSITION - LEFT_PROBE_BED_POSITION)
#define PROBE_AREA_DEPTH (BACK_PROBE_BED_POSITION - FRONT_PROBE_BED_POSITION)
#if X_PROBE_OFFSET_FROM_EXTRUDER < 0
#if PROBE_SIZE_X <= -PROBE_AREA_WIDTH
#define X_PROBE_ERROR
#endif
#elif PROBE_SIZE_X >= PROBE_AREA_WIDTH
#define X_PROBE_ERROR
#endif
#ifdef X_PROBE_ERROR
#error The X axis probing range is too small to fit all the points defined in AUTO_BED_LEVELING_GRID_POINTS
#endif
#if Y_PROBE_OFFSET_FROM_EXTRUDER < 0
#if PROBE_SIZE_Y <= -PROBE_AREA_DEPTH
#define Y_PROBE_ERROR
#endif
#elif PROBE_SIZE_Y >= PROBE_AREA_DEPTH
#define Y_PROBE_ERROR
#endif
#ifdef Y_PROBE_ERROR
#error The Y axis probing range is too small to fit all the points defined in AUTO_BED_LEVELING_GRID_POINTS
#endif
#undef PROBE_SIZE_X
#undef PROBE_SIZE_Y
#undef PROBE_AREA_WIDTH
#undef PROBE_AREA_DEPTH
#else // !AUTO_BED_LEVELING_GRID
// Check the triangulation points
#if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_1_X can't be reached by the probe."
#elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_2_X can't be reached by the probe."
#elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_3_X can't be reached by the probe."
#elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_1_Y can't be reached by the probe."
#elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_2_Y can't be reached by the probe."
#elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_3_Y can't be reached by the probe."
#endif
#endif // !AUTO_BED_LEVELING_GRID
#endif // ENABLE_AUTO_BED_LEVELING
/**
* ULTIPANEL encoder
*/
#if defined(ULTIPANEL) && !defined(NEWPANEL) && !defined(SR_LCD_2W_NL) && !defined(SHIFT_CLK)
#error ULTIPANEL requires some kind of encoder.
#endif
/**
* Delta has limited bed leveling options
*/
#ifdef DELTA
#ifdef ENABLE_AUTO_BED_LEVELING
#ifndef AUTO_BED_LEVELING_GRID
#error Only AUTO_BED_LEVELING_GRID is supported with DELTA.
#endif
#ifdef Z_PROBE_SLED
#error You cannot use Z_PROBE_SLED with DELTA.
#endif
#ifdef Z_PROBE_REPEATABILITY_TEST
#error Z_PROBE_REPEATABILITY_TEST is not supported with DELTA yet.
#endif
#endif
#endif
/**
* Allen Key Z Probe requires Auto Bed Leveling grid and Delta
*/
#if defined(Z_PROBE_ALLEN_KEY) && !(defined(AUTO_BED_LEVELING_GRID) && defined(DELTA))
#error Invalid use of Z_PROBE_ALLEN_KEY.
#endif
/**
* Dual X Carriage requirements
*/
#ifdef DUAL_X_CARRIAGE
#if EXTRUDERS == 1 || defined(COREXY) \
|| !HAS_X2_ENABLE || !HAS_X2_STEP || !HAS_X2_DIR \
|| !defined(X2_HOME_POS) || !defined(X2_MIN_POS) || !defined(X2_MAX_POS) \
|| !HAS_X_MAX
#error Missing or invalid definitions for DUAL_X_CARRIAGE mode.
#endif
#if X_HOME_DIR != -1 || X2_HOME_DIR != 1
#error Please use canonical x-carriage assignment.
#endif
#endif // DUAL_X_CARRIAGE
/**
* Make sure auto fan pins don't conflict with the fan pin
*/
#if HAS_AUTO_FAN && HAS_FAN
#if EXTRUDER_0_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_0_AUTO_FAN_PIN equal to FAN_PIN
#elif EXTRUDER_1_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_1_AUTO_FAN_PIN equal to FAN_PIN
#elif EXTRUDER_2_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_2_AUTO_FAN_PIN equal to FAN_PIN
#elif EXTRUDER_3_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_3_AUTO_FAN_PIN equal to FAN_PIN
#endif
#endif
#if HAS_FAN && CONTROLLERFAN_PIN == FAN_PIN
#error You cannot set CONTROLLERFAN_PIN equal to FAN_PIN
#endif
/**
* Test required HEATER defines
*/
#if EXTRUDERS > 3
#if !HAS_HEATER_3
#error HEATER_3_PIN not defined for this board
#endif
#elif EXTRUDERS > 2
#if !HAS_HEATER_2
#error HEATER_2_PIN not defined for this board
#endif
#elif EXTRUDERS > 1 || defined(HEATERS_PARALLEL)
#if !HAS_HEATER_1
#error HEATER_1_PIN not defined for this board
#endif
#endif
#if !HAS_HEATER_0
#error HEATER_0_PIN not defined for this board
#endif
/**
* Warnings for old configurations
*/
#ifdef X_HOME_RETRACT_MM
#error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM
#endif
#if WATCH_TEMP_PERIOD > 500
#error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds
#endif
#if !defined(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
#error Thermal Runaway Protection for hotends must now be enabled with THERMAL_PROTECTION_HOTENDS
#endif
#if !defined(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
#error Thermal Runaway Protection for the bed must now be enabled with THERMAL_PROTECTION_BED
#endif
#endif //SANITYCHECK_H