@ -371,6 +371,15 @@
#define MAX_PROBE_X (min(X_MAX_POS, X_MAX_POS + X_PROBE_OFFSET_FROM_EXTRUDER))
#define MIN_PROBE_Y (max(Y_MIN_POS, Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER))
#define MAX_PROBE_Y (min(Y_MAX_POS, Y_MAX_POS + Y_PROBE_OFFSET_FROM_EXTRUDER))
#ifndef XY_TRAVEL_SPEED
#ifdef HOMING_FEEDRATE_XYZ
#define XY_TRAVEL_SPEED HOMING_FEEDRATE_XYZ
#else
#define XY_TRAVEL_SPEED 4000
#endif
#endif
#endif
#define HAS_Z_SERVO_ENDSTOP (defined(Z_ENDSTOP_SERVO_NR) && Z_ENDSTOP_SERVO_NR >= 0)
@ -758,7 +767,7 @@
#define HAS_BED_PROBE (PROBE_SELECTED && PROBE_PIN_CONFIGURED)
/**
* Probe dependencies
* Bed Probe dependencies
*/
#if HAS_BED_PROBE
#ifndef X_PROBE_OFFSET_FROM_EXTRUDER

View file

@ -409,6 +409,57 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//============================= Z Probe Options =============================
//===========================================================================
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 10 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
// Enable Z_MIN_PROBE_ENDSTOP to use _both_ a Z Probe and a Z-min-endstop on the same machine.
// With this option the Z_MIN_PROBE_PIN will only be used for probing, never for homing.
//
@ -453,12 +504,20 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -606,27 +665,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 10 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -634,26 +672,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1147,14 +1165,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -1575,7 +1575,7 @@ static void setup_for_endstop_move() {
endstops.enable();
}
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
#if HAS_BED_PROBE
#if ENABLED(DELTA)
/**
@ -1592,6 +1592,71 @@ static void setup_for_endstop_move() {
}
#endif
/**
* Plan a move to (X, Y, Z) and set the current_position
* The final current_position may not be the one that was requested
*/
static void do_blocking_move_to(float x, float y, float z) {
float old_feedrate = feedrate;
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) print_xyz("do_blocking_move_to", x, y, z);
#endif
#if ENABLED(DELTA)
feedrate =
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
xy_travel_speed
#else
min(planner.max_feedrate[X_AXIS], planner.max_feedrate[Y_AXIS]) * 60
#endif
;
destination[X_AXIS] = x;
destination[Y_AXIS] = y;
destination[Z_AXIS] = z;
if (x == current_position[X_AXIS] && y == current_position[Y_AXIS])
prepare_move_to_destination_raw(); // this will also set_current_to_destination
else
prepare_move_to_destination(); // this will also set_current_to_destination
#else
feedrate = homing_feedrate[Z_AXIS];
current_position[Z_AXIS] = z;
line_to_current_position();
stepper.synchronize();
feedrate =
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
xy_travel_speed
#else
min(planner.max_feedrate[X_AXIS], planner.max_feedrate[Y_AXIS]) * 60
#endif
;
current_position[X_AXIS] = x;
current_position[Y_AXIS] = y;
line_to_current_position();
#endif
stepper.synchronize();
feedrate = old_feedrate;
}
inline void do_blocking_move_to_z(float z) {
do_blocking_move_to(current_position[X_AXIS], current_position[Y_AXIS], z);
}
#endif //HAS_BED_PROBE
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
#if ENABLED(AUTO_BED_LEVELING_GRID)
#if DISABLED(DELTA)
@ -1751,51 +1816,6 @@ static void setup_for_endstop_move() {
feedrate = old_feedrate;
}
/**
* Plan a move to (X, Y, Z) and set the current_position
* The final current_position may not be the one that was requested
*/
static void do_blocking_move_to(float x, float y, float z) {
float old_feedrate = feedrate;
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) print_xyz("do_blocking_move_to", x, y, z);
#endif
#if ENABLED(DELTA)
feedrate = xy_travel_speed;
destination[X_AXIS] = x;
destination[Y_AXIS] = y;
destination[Z_AXIS] = z;
if (x == current_position[X_AXIS] && y == current_position[Y_AXIS])
prepare_move_to_destination_raw(); // this will also set_current_to_destination
else
prepare_move_to_destination(); // this will also set_current_to_destination
#else
feedrate = homing_feedrate[Z_AXIS];
current_position[Z_AXIS] = z;
line_to_current_position();
stepper.synchronize();
feedrate = xy_travel_speed;
current_position[X_AXIS] = x;
current_position[Y_AXIS] = y;
line_to_current_position();
#endif
stepper.synchronize();
feedrate = old_feedrate;
}
inline void do_blocking_move_to_xy(float x, float y) {
do_blocking_move_to(x, y, current_position[Z_AXIS]);
}
@ -1804,10 +1824,6 @@ static void setup_for_endstop_move() {
do_blocking_move_to(x, current_position[Y_AXIS], current_position[Z_AXIS]);
}
inline void do_blocking_move_to_z(float z) {
do_blocking_move_to(current_position[X_AXIS], current_position[Y_AXIS], z);
}
inline void raise_z_after_probing() {
#if Z_RAISE_AFTER_PROBING > 0
#if ENABLED(DEBUG_LEVELING_FEATURE)
@ -2171,31 +2187,31 @@ static void setup_for_endstop_move() {
#endif // DELTA
#if HAS_Z_SERVO_ENDSTOP
/**
* Raise Z to a minimum height to make room for a servo to move
*
* zprobe_zoffset: Negative of the Z height where the probe engages
* z_dest: The before / after probing raise distance
*
* The zprobe_zoffset is negative for a switch below the nozzle, so
* multiply by Z_HOME_DIR (-1) to move enough away from the bed.
*/
void raise_z_for_servo(float z_dest) {
z_dest += home_offset[Z_AXIS];
if ((Z_HOME_DIR) < 0 && zprobe_zoffset < 0)
z_dest -= zprobe_zoffset;
if (z_dest > current_position[Z_AXIS])
do_blocking_move_to_z(z_dest); // also updates current_position
}
#endif
#endif // AUTO_BED_LEVELING_FEATURE
#if HAS_Z_SERVO_ENDSTOP
/**
* Raise Z to a minimum height to make room for a servo to move
*
* zprobe_zoffset: Negative of the Z height where the probe engages
* z_dest: The before / after probing raise distance
*
* The zprobe_zoffset is negative for a switch below the nozzle, so
* multiply by Z_HOME_DIR (-1) to move enough away from the bed.
*/
void raise_z_for_servo(float z_dest) {
z_dest += home_offset[Z_AXIS];
if ((Z_HOME_DIR) < 0 && zprobe_zoffset < 0)
z_dest -= zprobe_zoffset;
if (z_dest > current_position[Z_AXIS])
do_blocking_move_to_z(z_dest); // also updates current_position
}
#endif
#if ENABLED(Z_PROBE_SLED) || ENABLED(Z_SAFE_HOMING) || ENABLED(AUTO_BED_LEVELING_FEATURE)
static void axis_unhomed_error(bool xyz=false) {
if (xyz) {

View file

@ -420,10 +420,14 @@
#endif
/**
* Allen Key Z probe requires Auto Bed Leveling grid and Delta
* Allen Key Z probe requires Delta and Auto Bed Leveling grid
*/
#if ENABLED(Z_PROBE_ALLEN_KEY) && !(ENABLED(AUTO_BED_LEVELING_GRID) && ENABLED(DELTA))
#error "Invalid use of Z_PROBE_ALLEN_KEY."
#if ENABLED(Z_PROBE_ALLEN_KEY)
#if !ENABLED(DELTA)
#error "Z_PROBE_ALLEN_KEY is only usable with DELTA."
#elif ENABLED(MESH_BED_LEVELING) || (ENABLED(AUTO_BED_LEVELING_FEATURE) && !ENABLED(AUTO_BED_LEVELING_GRID))
#error "Z_PROBE_ALLEN_KEY can only use AUTO_BED_LEVELING_GRID leveling."
#endif
#endif
/**

View file

@ -408,6 +408,57 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//============================= Z Probe Options =============================
//===========================================================================
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 10 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
// Enable Z_MIN_PROBE_ENDSTOP to use _both_ a Z Probe and a Z-min-endstop on the same machine.
// With this option the Z_MIN_PROBE_PIN will only be used for probing, never for homing.
//
@ -452,12 +503,20 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 1
@ -605,27 +664,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 10 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -633,26 +671,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1150,14 +1168,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -435,12 +435,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -588,27 +647,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -616,25 +654,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1130,14 +1149,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -433,12 +433,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -586,27 +645,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -614,25 +652,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1128,14 +1147,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -445,12 +445,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -598,27 +657,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -626,25 +664,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1139,14 +1158,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -447,12 +447,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 34 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 15 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 5 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 5 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -600,27 +659,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 34 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 15 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 2 // How much the Z axis will be raised when traveling from between next probing points.
@ -628,26 +666,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1146,14 +1164,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -470,12 +470,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -623,27 +682,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -651,25 +689,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1164,14 +1183,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -453,12 +453,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -606,27 +665,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -634,25 +672,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1147,14 +1166,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -447,12 +447,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -600,27 +659,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -628,25 +666,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1144,14 +1163,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
#define NUM_SERVOS 0 // DGlass3D - Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -461,12 +461,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -614,27 +673,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -642,25 +680,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1155,14 +1174,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -474,12 +474,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -627,27 +686,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -655,25 +693,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1168,14 +1187,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -445,12 +445,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -598,27 +657,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -626,25 +664,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1139,14 +1158,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -453,12 +453,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -606,27 +665,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -634,25 +672,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1147,14 +1166,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -495,12 +495,108 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Just like Kossel Pro
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X -105.00 // Move left but not quite so far that we'll bump the belt
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y 0.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X -110.00 // Move outward to position deploy pin to the left of the arm
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_X 45.00 // Move right to trigger deploy pin
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_FEEDRATE (XY_TRAVEL_SPEED)/2
#define Z_PROBE_ALLEN_KEY_STOW_1_X 36.00 // Line up with bed retaining clip
#define Z_PROBE_ALLEN_KEY_STOW_1_Y -122.00
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 75.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_STOW_2_X 36.00 // move down to retract probe
#define Z_PROBE_ALLEN_KEY_STOW_2_Y -122.00
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 25.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED)/2
#define Z_PROBE_ALLEN_KEY_STOW_3_X 0.0 // return to 0,0,100
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 0.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE XY_TRAVEL_SPEED
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 50 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -652,27 +748,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 4000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -680,67 +755,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Just like Kossel Pro
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X -105.00 // Move left but not quite so far that we'll bump the belt
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y 0.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X -110.00 // Move outward to position deploy pin to the left of the arm
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_X 45.00 // Move right to trigger deploy pin
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_FEEDRATE (HOMING_FEEDRATE_XYZ)/2
#define Z_PROBE_ALLEN_KEY_STOW_1_X 36.00 // Line up with bed retaining clip
#define Z_PROBE_ALLEN_KEY_STOW_1_Y -122.00
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 75.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_STOW_2_X 36.00 // move down to retract probe
#define Z_PROBE_ALLEN_KEY_STOW_2_Y -122.00
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 25.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/2
#define Z_PROBE_ALLEN_KEY_STOW_3_X 0.0 // return to 0,0,100
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 0.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE HOMING_FEEDRATE_XYZ
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1236,14 +1250,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -495,12 +495,102 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (XY_TRAVEL_SPEED)/10
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED)/10
#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE XY_TRAVEL_SPEED
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 50 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -652,27 +742,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 4000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points
@ -680,61 +749,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE HOMING_FEEDRATE_XYZ
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1230,14 +1244,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -419,7 +419,7 @@
// extra connectors. Leave undefined any used for non-endstop and non-probe purposes.
//#define USE_XMIN_PLUG
//#define USE_YMIN_PLUG
//#define USE_ZMIN_PLUG
#define USE_ZMIN_PLUG
#define USE_XMAX_PLUG
#define USE_YMAX_PLUG
#define USE_ZMAX_PLUG
@ -495,12 +495,105 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Kossel Mini
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (XY_TRAVEL_SPEED/10)
#define Z_PROBE_ALLEN_KEY_STOW_DEPTH 20
// Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
// Move the nozzle down further to push the probe into retracted position.
#define Z_PROBE_ALLEN_KEY_STOW_2_X Z_PROBE_ALLEN_KEY_STOW_1_X
#define Z_PROBE_ALLEN_KEY_STOW_2_Y Z_PROBE_ALLEN_KEY_STOW_1_Y
#define Z_PROBE_ALLEN_KEY_STOW_2_Z (Z_PROBE_ALLEN_KEY_STOW_1_Z-Z_PROBE_ALLEN_KEY_STOW_DEPTH)
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED/10)
// Raise things back up slightly so we don't bump into anything
#define Z_PROBE_ALLEN_KEY_STOW_3_X Z_PROBE_ALLEN_KEY_STOW_2_X
#define Z_PROBE_ALLEN_KEY_STOW_3_Y Z_PROBE_ALLEN_KEY_STOW_2_Y
#define Z_PROBE_ALLEN_KEY_STOW_3_Z (Z_PROBE_ALLEN_KEY_STOW_1_Z+Z_PROBE_ALLEN_KEY_STOW_DEPTH)
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE (XY_TRAVEL_SPEED/2)
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 50 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -652,27 +745,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 4000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points
@ -680,64 +752,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Kossel Mini
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (XY_TRAVEL_SPEED/10)
#define Z_PROBE_ALLEN_KEY_STOW_DEPTH 20
// Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
// Move the nozzle down further to push the probe into retracted position.
#define Z_PROBE_ALLEN_KEY_STOW_2_X Z_PROBE_ALLEN_KEY_STOW_1_X
#define Z_PROBE_ALLEN_KEY_STOW_2_Y Z_PROBE_ALLEN_KEY_STOW_1_Y
#define Z_PROBE_ALLEN_KEY_STOW_2_Z (Z_PROBE_ALLEN_KEY_STOW_1_Z-Z_PROBE_ALLEN_KEY_STOW_DEPTH)
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED/10)
// Raise things back up slightly so we don't bump into anything
#define Z_PROBE_ALLEN_KEY_STOW_3_X Z_PROBE_ALLEN_KEY_STOW_2_X
#define Z_PROBE_ALLEN_KEY_STOW_3_Y Z_PROBE_ALLEN_KEY_STOW_2_Y
#define Z_PROBE_ALLEN_KEY_STOW_3_Z (Z_PROBE_ALLEN_KEY_STOW_1_Z+Z_PROBE_ALLEN_KEY_STOW_DEPTH)
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE (XY_TRAVEL_SPEED/2)
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1233,14 +1247,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -484,12 +484,110 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -23 // KosselPro actual: -22.919
#define Y_PROBE_OFFSET_FROM_EXTRUDER -6 // KosselPro actual: -6.304
// Kossel Pro note: The correct value is likely -17.45 but I'd rather err on the side of
// not giving someone a head crash. Use something like G29 Z-0.2 to adjust as needed.
#define Z_PROBE_OFFSET_FROM_EXTRUDER -17.25 // Increase this if the first layer is too thin (remember: it's a negative number so increase means closer to zero).
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Kossel Pro
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X -105.00 // Move left but not quite so far that we'll bump the belt
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y 0.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X -110.00 // Move outward to position deploy pin to the left of the arm
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z Z_PROBE_ALLEN_KEY_DEPLOY_1_Z
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_X 45.00 // Move right to trigger deploy pin
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Z Z_PROBE_ALLEN_KEY_DEPLOY_2_Z
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_FEEDRATE (XY_TRAVEL_SPEED)/2
#define Z_PROBE_ALLEN_KEY_STOW_1_X 36.00 // Line up with bed retaining clip
#define Z_PROBE_ALLEN_KEY_STOW_1_Y -125.00
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 75.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_STOW_2_X Z_PROBE_ALLEN_KEY_STOW_1_X // move down to retract probe
#define Z_PROBE_ALLEN_KEY_STOW_2_Y Z_PROBE_ALLEN_KEY_STOW_1_Y
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 0.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED)/2
#define Z_PROBE_ALLEN_KEY_STOW_3_X 0.0 // return to 0,0,100
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 0.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE XY_TRAVEL_SPEED
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 100 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -641,29 +739,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -23 // KosselPro actual: -22.919
#define Y_PROBE_OFFSET_FROM_EXTRUDER -6 // KosselPro actual: -6.304
// Kossel Pro note: The correct value is likely -17.45 but I'd rather err on the side of
// not giving someone a head crash. Use something like G29 Z-0.2 to adjust as needed.
#define Z_PROBE_OFFSET_FROM_EXTRUDER -17.25 // Increase this if the first layer is too thin (remember: it's a negative number so increase means closer to zero).
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -671,67 +746,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
// Kossel Pro
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X -105.00 // Move left but not quite so far that we'll bump the belt
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y 0.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X -110.00 // Move outward to position deploy pin to the left of the arm
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z Z_PROBE_ALLEN_KEY_DEPLOY_1_Z
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_X 45.00 // Move right to trigger deploy pin
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Y -125.00
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_Z Z_PROBE_ALLEN_KEY_DEPLOY_2_Z
#define Z_PROBE_ALLEN_KEY_DEPLOY_3_FEEDRATE (HOMING_FEEDRATE_XYZ)/2
#define Z_PROBE_ALLEN_KEY_STOW_1_X 36.00 // Line up with bed retaining clip
#define Z_PROBE_ALLEN_KEY_STOW_1_Y -125.00
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 75.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_STOW_2_X Z_PROBE_ALLEN_KEY_STOW_1_X // move down to retract probe
#define Z_PROBE_ALLEN_KEY_STOW_2_Y Z_PROBE_ALLEN_KEY_STOW_1_Y
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 0.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/2
#define Z_PROBE_ALLEN_KEY_STOW_3_X 0.0 // return to 0,0,100
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 0.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 100.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE HOMING_FEEDRATE_XYZ
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1238,14 +1252,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -493,12 +493,102 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0.0 // Z probe to nozzle X offset: -left +right
#define Y_PROBE_OFFSET_FROM_EXTRUDER 0.0 // Z probe to nozzle Y offset: -front +behind
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0.3 // Z probe to nozzle Z offset: -below (always!)
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (XY_TRAVEL_SPEED)/10
//#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
//#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
//#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
//#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
//#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
//#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED)/10
//#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
//#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
//#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE XY_TRAVEL_SPEED
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 20 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 20 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -650,27 +740,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0.0 // Z probe to nozzle X offset: -left +right
#define Y_PROBE_OFFSET_FROM_EXTRUDER 0.0 // Z probe to nozzle Y offset: -front +behind
#define Z_PROBE_OFFSET_FROM_EXTRUDER 0.3 // Z probe to nozzle Z offset: -below (always!)
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 10 // How much the Z axis will be raised when traveling from between next probing points.
@ -678,61 +747,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE HOMING_FEEDRATE_XYZ
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
//#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
//#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
//#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
//#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE HOMING_FEEDRATE_XYZ
//#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
//#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
//#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
//#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
//#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
//#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
//#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE HOMING_FEEDRATE_XYZ
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1235,14 +1249,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -456,12 +456,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -609,27 +668,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -637,25 +675,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1150,14 +1169,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.

View file

@ -443,12 +443,71 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
//
// Allen Key Probe is defined in the Delta example configurations.
//
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 15 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 1
@ -596,27 +655,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER -25 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 8000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points.
@ -624,25 +662,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1141,14 +1160,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.