* Unify M600 and M125 pause features
* Cleanup per thinkyhead's comments
* Rename filament_change_menu_response to advanced_pause_menu_response
* Include HAS_BED_PROBE in QUIET_PROBING
* Update gMax example file
* is_idle() is out of scope without the braces
* Convert FT-i3-2020 to Advance Pause names...
* Allow pause even if not printing
- fix broken `M421` due to less-than-careful optimization
- add HOME_AFTER_DEACTIVATE define to advanced config so not everyone has to rehome after steppers are deactivated
- misc. cleanups (remove unused label, unused variables)
- rename to PROBING_HEATERS_OFF
- move heater pausing functionality into thermalManager
- add variables, pause(), ispaused(), other functions
- add fan pausing functionality -> PROBING_FANS_OFF
- add probing_pause() wrapper
- move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
- example configs
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration)
- M665 B also sets the radius for manual calibration menu
- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard
- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define
Firmware was forgetting the z_fade_height in Planner, set by M420 Z<f>,
after each reset or loading settings from EEPROM. Added the float
z_fade_height to EEPROM-Storage, now remembers the value.
# This is the 1st commit message:
MCP4728 consistency & fix ultralcd.cpp
The MCP4728 DAC controls the stepper motor current strenth on the
PRINTRBOARD Rev F and RIGIDBOARD V2 boards.
PR #5792 on 9 FEB 2017 implemented default drive percentages but only on
the RIGIDBOARD V2.
This change moves the default settings to Configuration_adv.h.
Also, ultralcd.cpp won't compile because of a type def conflict.
Changed it to match the one in stepper_dac.cpp
===========================================================
reword stepper curent section for clarity
===========================================================
change name & improve comments
===========================================================
changed name from A4JP to SCOOVO_X9H per PR #6139
# This is the commit message #2:
fix typo
==============================================
clarified BLTouch calculation & changed comment delimitters/flags
I found it hard to pickout the various sections in this area so I
changed most comments from // style to /** ... */
Made the BLTouch calculation simpler and clarified the units of measure
for the result.
============================================
add changes to example configurations
============================================
add TinyBoy2 to this PR & add BLTouch Delay
The offset for Z_DUAL_ENDSTOP (z_endstop_adj) is already in Marlin.
This PR just makes it a configuration item.
z_endstop_adj is initialized in two places so both had to be modified.
The OLED is driven by an SSD1306, connected to the board via
I2C, the rotary encoder is connected to 3 GPIO pins.
Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
Made the double touch portion a conditional compile based on the
PROBE_DOUBLE_TOUCH flag.
==============================================
Bugfix
The current G38 only stopped a move if it involved the Z axis.
Moved all the G38 code to it's own section and put it where it would
always be executed no matter what axis was moving or if the endstop was
enabled.
Also added a comment to configuration_adv to alert the user the double
tap had to be turned on.
==============================================
Change G38 back to using Z_MIN_PROBE
There's no Z_MIN endstop if Z_DUAL_ENDSTOPS is enabled and you have them
set to the top of the gantry.
G38 started out as using the Z_MIN_PROBE pin. I don't remember why we
changed it to the Z_MIN endstop.