dot-bob
b0fd8f2d74
Add option to move Z on double-click when idle
2018-10-01 01:41:11 -05:00
Scott Lahteine
e78bdd654d
Clean up BABYSTEP options
2018-10-01 01:29:21 -05:00
Scott Lahteine
3c40933713
Remove trailing spaces, old comment
2018-09-30 20:47:06 -05:00
Thomas Moore
3286325044
Add TMC2130 sensorless probing
2018-09-29 18:54:14 -05:00
Victor Tseng
93839e2f73
Add option to enable/disable autoretract altogether ( #11904 )
2018-09-28 16:52:56 -05:00
Scott Lahteine
241168926d
Update some configs
2018-09-27 16:42:59 -05:00
Scott Lahteine
cee34f7290
Followup for BABYSTEP_HOTEND_Z_OFFSET ( #11916 )
2018-09-24 21:46:56 -04:00
teemuatlut
884ad75cb8
Update config files
2018-09-24 17:26:18 -04:00
InsanityAutomation
1104054d73
2.0 IDEX Independent z offset and other fixes ( #11862 )
...
* Add Formbot Raptor board
Co-Authored-By: InsanityAutomation <insanityautomation@users.noreply.github.com>
* Add a second Z probe Z offset
Co-Authored-By: InsanityAutomation <insanityautomation@users.noreply.github.com>
* Modify method to utilize live adjustment of hotend z offset
Should probably move config option to babystepping and rename as it may now apply to all multiextruder systems
* Move config item and catchup other code to current method
2018-09-24 09:40:48 -05:00
Scott Lahteine
ddcbf80f23
Followup for Z_TRIPLE_ENDSTOPS
2018-09-23 12:22:31 -04:00
Roxy-3D
d3d6be8210
Add MAX7219 reverse units option ( #11860 )
2018-09-19 18:54:51 -05:00
InsanityAutomation
f38570ac55
Add custom user menu title ( #11769 )
2018-09-19 15:04:34 -05:00
Scott Lahteine
f5c210d33d
Config changes supporting up to 6 extruders
2018-09-16 22:22:35 -05:00
Holger Müller
1a6f2b29b8
Add support for Triple-Z steppers/endstops
2018-09-16 00:35:58 -05:00
Scott Lahteine
f79a5a9dee
Tweak spacing of L6470 options
2018-09-12 23:18:11 -05:00
Sam Lane
1b6bc19427
Add external closed loop controller support
2018-09-10 03:17:17 -05:00
Marcio Teixeira
beb51c2d58
Show manual extrusion moves as relative in LCD
...
- Implements FR#11724
- Old behavior can be restored by commenting out MANUAL_E_MOVES_RELATIVE
2018-09-06 02:00:25 -05:00
Scott Lahteine
e3fc9aa35f
Update some config comments
2018-08-31 16:03:44 -05:00
Michael Triffon
f8c52c9c29
Azteeg X5 Mini WiFi support ( #11601 )
2018-08-21 23:58:26 -05:00
Scott Lahteine
2d3317a35b
Prettify Dual X Carriage description
2018-08-21 23:34:29 -05:00
Greg Nutt
a1a5367380
Smoothieboard V1.0/1.1 and A5984 support
2018-08-09 23:03:17 -05:00
Scott Lahteine
9c62c47579
[2.0.x] Fix Dual X Carriage tool change crash ( #11447 )
2018-08-03 20:47:29 -05:00
teemuatlut
fbcdf5eaeb
Simplify stepper driver per-axis selection
2018-07-25 02:47:43 -05:00
Roxy-3D
9660996cc3
Add Multi Unit Support for Max7219 to bugfix_2.0.0 ( #11285 )
...
* Add Multi Unit Support for Max7219 to bugfix_2.0.0
* Apply multi-MAX7219 to example configs
* Tweak some spacing, macros
2018-07-19 13:56:47 -05:00
Scott Lahteine
665ac1e4d0
Add POWER_LOSS_PIN support
2018-07-18 19:55:10 -05:00
Scott Lahteine
e0ab8acf19
Add "Marlin Dev Mode" option
2018-07-02 22:55:21 -05:00
Scott Lahteine
bd7f5848f1
Remove JUNCTION_DEVIATION_INCLUDE_E option ( #11147 )
2018-06-29 22:42:05 -05:00
etagle
5b49fccf80
Add stepper driver DIR delay configuration option
...
...and recommended pulse width configuration for A4988
2018-06-26 13:28:04 -05:00
Scott Lahteine
d4795e5b8e
[2.0.x] Tweaks and additions for MAX7219 ( #11034 )
2018-06-18 22:04:03 -05:00
Simon Jouet
e2aeda61ed
HAL for Espressif ESP32 Wifi
2018-06-13 19:33:35 -05:00
etagle
6f14bcaa3e
Add MAXIMUM_STEPPER_RATE, enforce in multi-stepping
...
The timing value should be properly set for ALL boards. The compiler will check and set maximum step rate calculations based on those values.
2018-06-10 16:02:47 -05:00
etagle
39a7e7720d
Adaptive multiaxis step smoothing
...
- Stepper bugs fixed
- Support MIXING_EXTRUDER with Linear Advance
- Miscellaneous cleanup
2018-06-10 16:02:47 -05:00
Scott Lahteine
8a376e6beb
Update MINIMUM_STEPPER_PULSE description
2018-06-10 00:13:03 -05:00
Scott Lahteine
2deff0d9b9
Fix/Improve junction deviation
...
- Respect axis max acceleration limits instead of forcing a fixed acceleration value.
- The `junction_unit_vec` ensures proper handling of entry and exit speeds even when the axes involved have different limits.
2018-05-31 20:09:53 -05:00
Scott Lahteine
2e139fe50f
Tweak configuration spacing
2018-05-26 18:33:51 -05:00
Scott Lahteine
931ab4ec40
Rename Junction Deviation options
2018-05-26 18:33:51 -05:00
Jiri Jaburek
43ddb29f9e
Add FAN_MAX_PWM for M106-controlled fans
2018-05-15 21:18:46 -05:00
Scott Lahteine
acacee80a2
Add JUNCTION_ACCELERATION_FACTOR to configs
...
Part of #10688
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-11 23:13:27 -05:00
Scott Lahteine
4d4bf7897d
Junction Deviation jerk limiting option
2018-05-08 10:08:54 -05:00
Scott Lahteine
840ff60952
Bring some configs up to date
2018-05-06 02:42:27 -05:00
nightdemonx
e911635fb1
Add thermocouple with AD8495 support
2018-05-02 08:43:16 -05:00
Scott Lahteine
05c33833e7
[2.0.x] Add NO_LCD_MENUS option ( #10582 )
2018-04-30 21:16:31 -05:00
Scott Lahteine
11ab017dd0
Creality3D Power-Loss Recovery
2018-04-21 21:56:50 -05:00
Marcio Teixeira
5cc7916e69
Add G29_RETRY_AND_RECOVER feature
...
- Add an option to retry G29, optionally executing a G-code procedure after each failed probe.
2018-04-19 19:45:53 -05:00
Sean
2d9b0a66fe
Add Filament Change accelerations
2018-04-09 23:57:27 -05:00
Lenbok
0e8242180d
Chamber temperature monitoring and auto fan control.
...
This is an initial cut for feedback, updated for 2.0.x.
Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?
Chamber temperatures are not reported on the LCD in any way.
When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.
As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
Sean
2fa0a73c2c
Implement filament change continuous purge
2018-04-04 20:57:51 -05:00
Scott Lahteine
1d22609473
MIN_PROBE_EDGE replaces DELTA_PROBEABLE_RADIUS
2018-03-19 04:11:46 -05:00
Marcio Teixeira
c24dbcbfe1
When STATUS_EXPIRE_SECONDS is 0, hide the position. ( #10081 )
...
Some users may prefer to hide the position updates on the `LIGHTWEIGHT_UI` altogether. This leads to an even less cluttered display (it also saves on SPI traffic and one byte of RAM).
2018-03-14 02:44:30 -05:00
Studiodyne
e7a61de8af
[2.0] FWRetract Reset (Best way) ( #10083 )
2018-03-14 01:35:30 -05:00